Physical characteristics of the ECAT 953B/31: a new high resolution brain positron tomograph
B Mazoyer1, R Trebossen, R Deutch
1Service Hospitalier Frederic Joliot, CEA, Orsay.
Abstract:
A high spatial resolution brain positron tomograph, the ECAT 953B/31, is presented. The machine consists of two 76.5 cm diameter rings (patient port diameter: 36 cm) made of 24 8x8 BGO detector blocks each, each block being coupled to four 1 in(2) Hammamatsu phototubes. The machine has 15 9 cmx1 mm motorized removable septa, which allows reconstruction of 31 slices 3.375 mm apart. The transaxial resolution (FWHM) in the reconstructed image (with wobbling) is 4.5 mm at center, 5.2 mm (tangential) and 5.6 mm at 10 cm from center. With septa out of the field of view (FOV), the axial resolution degrades to 5.5 mm a center and 6.3 mm at 10 cm from center. At 1 muCi/cc with a 250 keV threshold and a 12 ns coincidence window, the sensitivity is 146100 true events, the ratio of randoms to trues is 0.10, the scatter fraction is 17% and the dead-time losses are 30%. With septa out of the FOV, the sensitivity is increased by a factor 3.6, while the scatter fraction reaches 0.9. Images obtained with (18 )F-DG and H(2)(15)O in human brains and (18 )F-DOPA in a baboon brain demonstrate that the ECAT 953B/31 will be suitable for high resolution and for low count rate brain studies.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies III: Computed Tomography