Related Experiment Video
Updated: Jul 7, 2026

Electrochemical Preparation of Poly(3,4-Ethylenedioxythiophene) Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Determination of 4-ethylcatechol in wine by high-performance liquid chromatography-coulometric electrochemical array
R Larcher1, G Nicolini, D Bertoldi
1IASMA Research Center, Agrifood Quality Department, via Mach 1, 38010 San Michele all'Adige (TN), Italy. roberto.larcher@ismaa.it
Abstract:
A HPLC method using a coulometric electrode array detector (CEAD) to analyse 4-ethylcatechol in wine was established. The procedure does not require any sample preparation or analyte derivatisation and performs chromatographic separation in a short time. The assay method is linear up to 1520microgL(-1) and precise (R.S.D.<3%), with limits of detection and quantitation of 1.34microgL(-1) and 2.2microgL(-1), respectively. Recoveries in spiked wine samples ranged from 95% to 104% with a median value of 102% and matrix effects were not observed. The method was applied to the evaluation of the concentration of 4-EC in 250 commercial Italian wines. The red wines analysed had median, 75 degrees percentile and maximum values of 37microgL(-1), 89microgL(-1) and 1610microgL(-1), respectively. For Sangiovese-based wines the mean ratios of 4-EP and 4-EG to 4-EC were 3.7:1 and 0.7:1, respectively. The feasibility of a cheaper fluorimetric approach to 4-EC quantification was investigated.
More Related Videos
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
10:11Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...