Related Experiment Video
Updated: Jun 28, 2026

10:22
In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions
Published on: June 16, 2014
The MAXEBIS at GSI as a test ion source for charge breeding and for HITRAP
The Review of Scientific Instruments
|March 5, 2008
Summary
The MAXEBIS electron beam ion source was installed at GSI for charge breeding tests. Beam transport simulations and modifications improved efficiency, with first measurements of injection and breeding efficiency determined.
Area of Science:
- Atomic Physics
- Accelerator Physics
Background:
- The MAXEBIS electron beam ion source, developed at the University of Frankfurt, is crucial for charge breeding research.
- Its installation at GSI facilitates offline testing for the HITRAP project and advanced charge breeding explorations.
Purpose of the Study:
- To characterize the performance of the MAXEBIS electron beam ion source.
- To investigate and mitigate beam losses during ion injection and transport.
- To determine the injection and breeding efficiency of the MAXEBIS for the first time.
Main Methods:
- Installation of new diagnostics and beam optics.
- Utilizing two external ion sources for singly charged ion production.
- Employing SIMION code for beam transport simulation and beamline modification.
- Measuring beam emittance using a nondestructive beam profile method.
- Analyzing electron current density via charge state analysis of time-of-flight (TOF) spectra.
Main Results:
- First time-of-flight (TOF) spectra of charge-bred argon ions were obtained.
- Beam losses were identified in the transport line from the multipassage spectrometer (MPS) to MAXEBIS.
- SIMION simulations led to modifications that addressed beam transport issues.
- Injection and breeding efficiencies of the MAXEBIS were quantified for the first time.
Conclusions:
- The study successfully characterized the MAXEBIS electron beam ion source.
- Simulations and modifications effectively addressed beam transport losses.
- The determined injection and breeding efficiencies provide critical data for future experiments.
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Electrospray Ionization (ESI) Mass Spectrometry
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...