Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and
V K Gupta1, A K Singh, Barkha Gupta
1Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee, 247667, India. vinodfcy@iitr.ernet.in
Abstract:
A new highly selective terbium(III) electrode was prepared with a polymeric film doped using S-2-benzothiazolyl-2-amino-alpha-(methoxyimino)-4-thiazolethiol acetate as an electroactive material, benzyl acetate (BA) as a plasticizer, and potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic site in the percentage ratio 3.17:1.58:63.4:31.7 (ionophore-KTpClPB-BA-PVC, w/w). The electrode exhibited a linear response with a near Nernstian slope of 19.5 mV/decade within the concentration range 1.5 x 10(-7)-1.0 x 10(-2) M terbium ions, with a working pH range from 2.0 to 8.0, and a fast response time of 10 s and presented satisfactory reproducibility. The limit of detection was 9.3 x 10(-8) M. The results show that this electrode can be used in ethanol media up to 30% (v/v) concentration without interference. It can be used for 3 months without any considerable divergence in the potentials. Selectivity coefficients for terbium(III) with respect to many cations were investigated. The electrode is highly selective for terbium(III) ions over a large number of monovalent, bivalent, and trivalent cations. This shows the valuable property of the proposed electrode. The stability constant of the ionophore towards Tb(3+) ions was determined with the sandwich membrane method. It was successfully used as an indicator electrode in potentiometric determination of terbium(III) ions with EDTA and in direct determination in tap water and binary mixtures with quantitative results. The utility of the proposed electrode was also determined in the presence of ionic and nonionic surfactants and in the presence of fluoride ions in four pharmaceutical (mouthwash) preparations. [figure: see text]
Related Concept Videos
Ion-Exchange Chromatography
Potentiometry: Membrane Electrodes
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
High-Performance Liquid Chromatography: Types of Detectors