Related Experiment Video
Updated: Jul 6, 2026

Cavernous Nerve Stimulation and Recording of Intracavernous Pressure in a Rat
Published on: April 23, 2018
Perioperative concentrations of catecholamines in the cerebrospinal fluid and plasma during spinal anesthesia
M J Oehmke1, T Podranski, M Mann
1Department of Special Anaesthesia and Pain Control, Medical University of Vienna, Vienna, Austria.
Background:
Catecholamine release is a physiological response to stress. The extent to which perioperative stress provokes the central release of catecholamines, which modulate pain perception in the spinal cord, still remains unknown. The perioperative course of catecholamine concentrations in the cerebrospinal fluid (CSF) and plasma was examined.
Methods:
A prospective study was performed in 25 patients (ASA III, 60-84 years) undergoing elective hip joint replacement in spinal catheter anesthesia. The concentrations of dopamine, epinephrine and norepinephrine in the CSF and plasma were measured before anesthesia, immediately after surgery, and 6 and 24 h post-operatively.
Results:
In most patients, dopamine and epinephrine were not detectable in CSF. CSF-norepinephrine concentrations decreased from median [interquartile-range] 159 [124;216] pre-anesthesia to 116 [79;152] pmol/l immediately post-operatively and were slightly elevated 24 h post-operatively (180 [134;302] pmol/l) (P=0.05). Dopamine plasma concentrations were not detectable or were barely above the detection threshold. Plasma epinephrine increased from 61 [28;77] pmol/l pre-anesthesia to 112 [69;138] pmol/l 6 h post-operatively and returned to baseline 24 h post-operatively (P=0.001). Plasma norepinephrine concentrations increased intra-operatively from 298 [249;422] to 556 [423;649] pmol/l and remained elevated 24 h after surgery (P=0.009). There was no association between changes in CSF or plasma norepinephrine or epinephrine concentrations and changes in heart rate (HR) or mean arterial pressure (MAP).
Conclusion:
During spinal anesthesia for elective hip joint replacement, norepinephrine concentrations were greater in plasma than in CSF. CSF dopamine and epinephrine concentrations were essentially undetectable. The changes in CSF-norepinephrine concentrations and the changes of plasma norepinephrine concentrations showed no association with each other; nor were there correlations between clinical stress parameters (HR, MAP) or visual analog scale pain, and the changes in CSF norepinephrine concentrations.
Related Concept Videos
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Parenteral Anesthetics: Overview