Related Experiment Video
Updated: Jul 6, 2026

Colorimetric Assessment of Deiodinase 1 Activity in Human Liver Microsomes Using the Sandell-Kolthoff Reaction
Published on: April 10, 2026
Reference values for spot urinary iodine concentrations in iodine-sufficient newborns using a new pad collection
Corine M Dorey1, Michael B Zimmermann
1Laboratory for Human Nutrition, Swiss Federal Institute of Technology (ETH), Zürich, Switzerland.
A new pad system effectively collects infant urine samples for iodine testing. Newborn urinary iodine concentration (UIC) data suggest the WHO sufficiency threshold may be too high for early infancy.
Area of Science:
- Pediatric Nutrition
- Biochemical Monitoring
- Public Health
Background:
- Infant iodine deficiency can negatively impact neurocognitive development.
- Limited indicators exist for assessing iodine intake in newborns.
- High access to newborns in maternity clinics presents an opportunity for early assessment.
Purpose of the Study:
- To develop and validate a simple pad system for collecting infant spot urine samples for iodine analysis.
- To establish reference ranges for urinary iodine concentration (UIC) in newborns within the first week of life.
- To aid in monitoring iodine nutrition status in early infancy.
Main Methods:
- A two-stage cluster sampling method was employed to select a national sample of healthy, term Swiss infants (n=634).
- Spot urine samples were collected on two consecutive days from infants aged 0-5 days.
- Thyrotropin levels and gestational information were also collected.
Main Results:
- The pad collection system demonstrated good performance and acceptance in testing.
- The median urinary iodine concentration (UIC) in the total sample (n=1224) was 77 microg/L.
- UIC showed a gradual increase from day 1 to day 4, and the UI:creatinine ratio was not a reliable standardization method due to high creatinine variability.
Conclusions:
- The current WHO median UIC cut-off for iodine sufficiency (>100 microg/L) may be inappropriate for newborns in their first week.
- Establishing reference data for UIC in newborns is crucial for accurate iodine status assessment.
- A simple collection system and newborn reference data can improve the utility of UIC monitoring in infants.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Urine Studies II: Urine Culture and Sensitivity Test
Urine Studies I: Urinalysis