Precision test of mass-ratio variations with lattice-confined ultracold molecules

T Zelevinsky1, S Kotochigova, Jun Ye

  • 1JILA, National Institute of Standards and Technology and University of Colorado, Boulder, Colorado 80309-0440, USA.

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Trends in Lattice Energy: Ion Size and Charge02:54

Trends in Lattice Energy: Ion Size and Charge

An ionic compound is stable because of the electrostatic attraction between its positive and negative ions. The lattice energy of a compound is a measure of the strength of this attraction. The lattice energy (ΔHlattice) of an ionic compound is defined as the energy required to separate one mole of the solid into its component gaseous ions. For the ionic solid sodium chloride, the lattice energy is the enthalpy change of the process:
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Crystal Density01:19

Crystal Density

The crystal lattice structure of a material allows us to determine how many molecules exist in its unit cell. With this information, alongside the unit-cell parameters - three distance parameters (a, b, c) and three angular parameters (α, β, γ).Density (ρ) = (Z × M) / (a × b × c × NA)where:Z is the number of formula units per unit cellM is the molar mass of the substancea, b, and c are the edge lengths of the unit cellNA is Avogadro’s numberFor a simple cubic lattice, atoms are located only at...