Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Extraction of optical properties from scattering media using a convolutional neural network and diverse exit information.

Optics letters·2025
Same author

Imaging textural variation in the acoustoelastic coefficient of aluminum using surface acoustic waves.

The Journal of the Acoustical Society of America·2015
Same author

The use of simultaneous fluorescence and differential phase confocal microscopy to study alamar blue™ reduction in an epithelial cell line.

Alternatives to laboratory animals : ATLA·2015
Same author

Determination of the acoustoelastic coefficient for surface acoustic waves using dynamic acoustoelastography: an alternative to static strain.

The Journal of the Acoustical Society of America·2014
Same author

Spatial modulation microscopy for real-time imaging of plasmonic nanoparticles and cells.

Optics letters·2012
Same author

Surface plasmon microscopy: resolution, sensitivity and crosstalk.

Journal of microscopy·2012

Related Experiment Video

Updated: Jul 6, 2026

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons
07:39

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons

Published on: July 21, 2018

High-resolution scanning surface-plasmon microscopy.

M G Somekh1, S Liu, T S Velinov

  • 1School of Electrical and Electronic Engineering, University Park, Nottingham NG7 2RD, UK. mike.somekh@nottingham.ac.uk

Applied Optics
|March 21, 2008
PubMed
Summary
This summary is machine-generated.

Surface plasmons (SPs) are sensitive to dielectric changes, enabling sensor applications. Novel microscopy techniques overcome resolution limits for enhanced biological imaging.

More Related Videos

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

Evaluating Plasmonic Transport in Current-carrying Silver Nanowires
09:00

Evaluating Plasmonic Transport in Current-carrying Silver Nanowires

Published on: December 11, 2013

Related Experiment Videos

Last Updated: Jul 6, 2026

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons
07:39

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons

Published on: July 21, 2018

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

Evaluating Plasmonic Transport in Current-carrying Silver Nanowires
09:00

Evaluating Plasmonic Transport in Current-carrying Silver Nanowires

Published on: December 11, 2013

Area of Science:

  • Physics
  • Optics
  • Materials Science

Background:

  • Surface plasmons (SPs) are electromagnetic waves at conductor-dielectric interfaces.
  • SPs exhibit high sensitivity to changes in dielectric properties, making them valuable for sensors.
  • Microscopic applications of SPs are typically limited by lateral resolution to several micrometers.

Purpose of the Study:

  • To overcome the lateral resolution limitations of surface plasmon microscopy.
  • To demonstrate enhanced resolution in SP imaging comparable to high-numerical-aperture optical microscopy.
  • To explore the potential of ultrahigh-numerical-aperture objectives for biological imaging.

Main Methods:

  • Utilizing defocused high-numerical-aperture liquid-immersion objectives for SP imaging.
  • Presenting surface plasmon images to showcase achieved resolution.
  • Discussing the impact of objectives with numerical apertures exceeding 1.5.

Main Results:

  • Achieved lateral resolution in SP imaging comparable to high-numerical-aperture optical microscopes.
  • Demonstrated a method to surpass the micrometer-scale resolution limit in SP microscopy.
  • Provided evidence for the influence of advanced objectives on imaging capabilities.

Conclusions:

  • Defocused high-numerical-aperture liquid-immersion objectives effectively enhance surface plasmon microscopy resolution.
  • Ultrahigh-numerical-aperture objectives hold significant promise for advancing biological imaging applications.
  • Surface plasmon microscopy, with improved optics, offers a powerful tool for nanoscale sensing and imaging.