Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Comparison of techniques for corneal power assessment after myopic LASIK without the use of preoperative data
Arthur C K Cheng1, Srinivas S K Rao, Silvania Lau
1Department of Ophthalmology and Visual Sciences, Chinese University of Hong Kong, Hong Kong Eye Hospital, Kowloon, Hong Kong. artcheng@netvigator.com
Purpose:
To compare the accuracy of different corneal power assessment techniques that do not require preoperative information with the clinical history method.
Methods:
This retrospective study analyzed 50 eyes of 50 patients using 3-month postoperative data. Net corneal powers were obtained with each of the following methods: Maloney, Wang, Sonego-Krone, Srivannaboon, Shammas, Orbscan flat axis, and Gaussian optics formula with Orbscan. Results were compared to the clinical history method using paired sample t test, Bland-Altman plots, and linear regression.
Results:
Both the Gaussian optics formula and Wang method were not significantly different from the clinical history method. The Sonego-Krone method significantly underestimated the corneal power, whereas the Maloney, Srivannaboon, Shammas, and Orbscan flat axis methods significantly overestimated the corneal power.
Conclusions:
The Gaussian optics formula and Wang method yielded comparable results with the clinical history method for assessing corneal power. The Gaussian optics formula produced the smallest standard deviation.