How have wear testing and joint simulator studies helped to discriminate among materials and designs?
Harry A McKellop1, Darryl D'Lima,
1Department of Orthopaedic Surgery, UCLA-Orthopaedic Hospital, Los Angeles, CA, USA.
Abstract:
Historically, hip joint simulators most often have been used to model wear of a bearing surface against a bearing surface. These simulators have provided highly accurate predictions of the in vivo wear of a broad spectrum of bearing materials, including cross-linked polyethylenes, metal-on-metal, ceramic-on-ceramic, and others in development. In recent years, more severe conditions have been successfully modeled, including jogging, stair climbing, ball-cup micro separation, third-body abrasion, and neck-socket impingement. These tests have served to identify improved materials and to eliminate some with inadequate wear resistance prior to their clinical use. Simulation of the knee joint is inherently more complex than it is for the hip. It is more difficult to compare the results of laboratory tests with actual clinical performance, due to the lack of accurate in vivo measures of wear. Nevertheless, knee simulators, based on force control or motion control, have successfully reproduced the type of surface damage that occurs in vivo (eg, burnishing, scratching, pitting) as well as the size and shapes of the resultant wear particles. Knee simulators have been used to compare molded versus machined polyethylene components, highly cross-linked polyethylenes, fixed versus mobile bearings, and oxidized zirconia and other materials, under optimal conditions as well as more severe wear modes, such as malalignment, higher loading and activity levels, and third-body roughening.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Design Example: Joints in Concrete Pavements
Contraction joints are typically formed by sawing a groove into the concrete shortly after it has hardened. This creates a weakened vertical plane, deliberately encouraging cracking at...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Design Example: Managing Concrete Workability
To address...