Related Experiment Video
Updated: Jul 3, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Evaluation of use of a very short polar microbore column segment in high-speed gas chromatography analysis
Peter Quinto Tranchida1, Monica Mondello, Danilo Sciarrone
1Dipartimento Farmaco-Chimico, Facoltà di Farmacia, Università di Messina, Messina, Italy.
Abstract:
Very fast GC analyses are commonly carried out by using 10 m x 0.1 mm id capillaries. In order to achieve rapid elution times (1-3 min), the latter are operated under suboptimum conditions. The present research is focused on the evaluation of use of a 0.1 mm id polar column segment (2 m), operated under near-to-optimum conditions, in very fast GC analysis. The results attained are compared with those derived from using a 10 m microbore column in very fast GC experiments. Prior to method development, the effects of gas velocity, temperature program rate, and sample amounts on analytical performance were evaluated. Following these preliminary applications, a complex lipidic sample, cod liver oil, was subjected to rapid separation (approximately 2.1 min) on the 10 m capillary through the application of a 50 degrees C/min temperature rate and a 130 cm/s gas velocity. The same matrix was analyzed on the 2 m capillary using the same temperature program rate and range, but with a close-to-ideal linear velocity. The results observed were of interest, as the separation was achieved in less time (1.45 min) with improved peak resolution. Finally, both methods were validated in terms of retention time and peak area repeatability, LOQ, and linearity.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Ion-Exchange Chromatography