A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Non-invasive measurement of intra-abdominal pressure: a preliminary study
G H van Ramshorst1, J F Lange, R H M Goossens
1Department of Surgery, Erasmus University Medical Center, PO Box 2040, 3000 CA Rotterdam, The Netherlands.
Abstract:
The importance of measuring intra-abdominal pressure (IAP) has increased since the negative effects of sustained increased IAP, also known as intra-abdominal hypertension (IAH), have become known. The relation between IAP and abdominal wall tension has been included in several reports. We have developed a device to measure abdominal wall tension by measuring force and distance. This device enables us to investigate the correlation between the abdominal wall tension and IAP. The abdomens of two corpses (one female, one male) were insufflated with air. IAP was increased and measured at intervals by means of a laparoscopic set-up. Abdominal tension was measured at seven points on the abdominal wall at each interval. Pearson's correlation coefficients were used to determine the relationship between IAP and tension for each point measured. ANOVA was used to assess relations between measured tensions versus applied pressure, locations and subjects. In both corpses, all points showed significant (p < 0.001) correlations between IAP and abdominal wall tension. The points along the mid transverse plane appear to be more similar compared to more cranial and caudal points. We have assessed the feasibility of a device that non-invasively can track changes in IAP. Measurements performed with the device are preliminary results, and further investigation is needed.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Abdomen III: Palpation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...