A Bland-Altman analysis of the bias between computed tomography and ultrasound prostate volume measurements
Aime Gloi1, Stephen McCourt, Corrie Zuge
1Department of Radiation Oncology, St. Vincent Hospital, Green Bay, WI 54301, USA. agloi@stvgb.org
Abstract:
This study assesses the agreement between computed tomography (CT) measurements of prostate volume and those obtained by ultrasound (US), a well-established non-invasive technique. Twenty-six patients aged between 58 and 74 years were evaluated for prostate seed implant therapy using both CT and US measurements. The level of agreement between these 2 methods, which were strongly correlated (R2 = 0.828; p < 0.0001), was determined through Bland-Altman analysis. The mean prostate volume (+/- one standard deviation) of the sample was 31.8 +/- 10.5 cc for the CT method and 27.0 +/- 8.2 cc for the US method. The prostate volumes obtained by CT were, on average, 17% larger than the corresponding volumes determined by US. The average bias between the 2 imaging methods is 4.80 cc or 15%, which is significantly larger than the clinically acceptable margin of 10%.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...