Related Experiment Video
Updated: Jul 2, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
The effective atomic number of dosimetric gels
M L Taylor1, R D Franich, J V Trapp
1Applied Physics, RMIT University, Melbourne, Australia. michael.taylor@rmit.edu.au
Abstract:
Radiological properties of gel dosimeters and phantom materials are often compared against each other and against water or tissue by consideration parameters including their effective atomic number, Zeff. Effective atomic numbers have been calculated for a range of ferrous-sulphate and polymeric gel dosimeters using mass attenuation coefficient data over the energy range 10 keV to 10 MeV. Data is presented relative to water to allow direct comparison over a range of energies. These data provide energy specific values of Zeff which improves on the practice of applying a power-law based formula to estimate an energy independent value. For applications that require a single value of Zeff, the data presented here allows the choice of a value appropriate to the energy of the photon source or a spectrum-weighted average. Studying the variation of Zeff, which is equivalent to taking into account the variation of mass attenuation coefficients with photon energy, it is found that gels typically match water better than water matches human tissues. As such, the subtle differences in effective atomic number between water and gels are small and may be considered negligible. Consideration of the mean disparity over a large energy range shows, broadly, BANG-1 to be the most water equivalent gel.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Biological Effects of Radiation
Atomic Radii and Effective Nuclear Charge
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Isotopes and Radioisotopes
An isotope containing more...
Nuclear Stability
To hold positively charged protons together in the...
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current