Flow cytometric analysis of mitochondrial membrane potential using JC-1

A Cossarizza1, S Salvioli

  • 1University of Modena, Modena, Italy.

Summary

This study highlights recent advances in fluorescent probes for measuring mitochondrial membrane potential. The JC-1 probe allows for quantitative analysis of membrane potential changes using flow cytometry.

Related Concept Videos

Mitochondrial Membranes01:45

Mitochondrial Membranes

A single mitochondrion is a bean-shaped organelle enclosed by a double-membrane system. The outer membrane of mitochondria is smooth and contains many porins - the integral membrane transporters. Porins enable free diffusion of ions and small uncharged molecules through the outer mitochondrial membrane but limit the transport of molecules larger than 5000 Daltons. Further, the outer mitochondrial membrane forms a unique structure called membrane contact sites with other subcellular organelles,...
Mitochondrial Membranes01:45

Mitochondrial Membranes

A single mitochondrion is a bean-shaped organelle enclosed by a double-membrane system. The outer membrane of mitochondria is smooth and contains many porins - the integral membrane transporters. Porins enable free diffusion of ions and small uncharged molecules through the outer mitochondrial membrane but limit the transport of molecules larger than 5000 Daltons. Further, the outer mitochondrial membrane forms a unique structure called membrane contact sites with other subcellular organelles,...
Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
Coulometry: Overview01:00

Coulometry: Overview

Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
The Inner Mitochondrial Membrane01:28

The Inner Mitochondrial Membrane

The inner mitochondrial membrane is the primary site of ATP synthesis. The inner membrane domain that forms a smooth layer adjacent to the outer membrane is called the inner boundary membrane. This domain contains membrane transporters that drive metabolites in and out of the mitochondria.  In contrast, the inner membrane network that invaginates into the matrix space is called the cristae membrane. This domain accounts for principle mitochondrial function as it accommodates the protein...