Related Experiment Video
Updated: Jun 30, 2026

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass
Steve Shiraishi1, Paul W N Lee, Andrew Leung
1General Clinical Research Center, Division of Endocrinology and Metabolism, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, Torrance, CA 90509, USA.
Background:
Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses.
Methods:
We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive-mode electrospray ionization.
Results:
The DHT and T calibrators showed a linear response from 0.069 nmol/L to 34.4 nmol/L and 69.3 nmol/L, respectively. T interference in the DHT assay and vice versa were negligible. Within- and between-run imprecision values were <5% for both analytes. Percent recoveries of T and DHT spiked into samples at concentrations spanning the calibration curve were 100%-113% and 98%-107%, respectively. The lower limit of quantification was 0.069 nmol/L for both steroids. Serum T concentrations measured by LC-MS/MS were different from those obtained by RIA, especially at lower T concentrations. Serum DHT concentrations measured by LC-MS/MS were markedly lower than those generated by RIA because of the nonselectivity of the RIA without chromatography. The reference intervals (mean +/- 2 SDs) determined for T and DHT were 9.2-33.7 nmol/L and 0.47-2.65 nmol/L, respectively, for 113 healthy adult men and 0.33-2.02 nmol/L and 0.09-0.91 nmol/L, respectively, for 133 healthy premenopausal women.
Conclusions:
We have developed and validated a selective and precise method for simultaneous measurements of serum T and DHT that can be adopted for routine measurements of these androgens in health and disease in men and women.
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...