Related Experiment Video
Updated: Jun 29, 2026

Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System
Published on: May 5, 2018
Fetal pulse oximetry: correlation with intrapartum fetal heart rate patterns and neonatal outcome
Arzu Tekin1, Sebiha Ozkan, Eray Calişkan
1Kocaeli University, School of Medicine, Department of Obstetrics and Gynecology, Kocaeli, Turkey.
Aim:
To determine how fetal pulse oximetry behaves in various cardiotocographic (CTG) tracings and correlates with neonatal outcome.
Patients And Methods:
Pregnant women undergoing active labor with singleton pregnancies of 32-42 weeks were enrolled. CTG recordings were reassuring or nonreassuring (namely variable or persisting late decelerations). Pulse oximetry values during labor and changing throughout deceleration and recovery phases, duration and frequency of pulse oximetry recordings <30%, and neonatal outcome were determined. One-way anova, Tukey test, chi(2)-test and multiple logistic regression model were used for statistical analysis where appropriate.
Results:
A total of 156 pregnant subjects were divided into three groups: reassuring fetal heart rate (FHR) patterns (group 1, n=78 [50%]), late decelerations (group 2, n=16 [10.3%]) and variable decelerations (group 3, n=62 [39.7%]). The initial and final pulse oximetry readings, pulse values in first stage of labor, the duration and the frequency of pulse oximetry recordings <30% were significantly different between groups (P<0.001, P<0.001, P<0.001, P=0.001, P<0.001). Fetal acidosis was significantly more frequent with late decelerations (23.1%, P=0.004). A multiple logistic regression model demonstrated that the initial pulse oximetry value during active labor was the most predictive variable of neonatal well-being (P<0.001).
Conclusion:
Decreased fetal pulse oximetry values, especially prolonged and recurrent recordings <30% are well-correlated with abnormal FHR patterns, indicating an association with fetal compromise and metabolic acidosis. Going through active labor with a lower initial value of FSpO(2) more frequently leads to an altered FHR pattern and subsequent adverse fetal outcome.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring pulse
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...