Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not
Berend E Westerhof1, Ilja Guelen, Wim J Stok
1BMEYE B.V., Academic Medical Center, Suite K2-245, Univ. of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. berend.westerhof@bmeye.com
Abstract:
Central aortic pressure gives better insight into ventriculo-arterial coupling and better prognosis of cardiovascular complications than peripheral pressures. Therefore transfer functions (TF), reconstructing aortic pressure from peripheral pressures, are of great interest. Generalized TFs (GTF) give useful results, especially in larger study populations, but detailed information on aortic pressure might be improved by individualization of the TF. We found earlier that the time delay, representing the travel time of the pressure wave between measurement site and aorta is the main determinant of the TF. Therefore, we hypothesized that the TF might be individualized (ITF) using this time delay. In a group of 50 patients at rest, aged 28-66 yr (43 men), undergoing diagnostic angiography, ascending aortic pressure was 119 +/- 20/70 +/- 9 mmHg (systolic/diastolic). Brachial pressure, almost simultaneously measured using catheter pullback, was 131 +/- 18/67 +/- 9 mmHg. We obtained brachial-to-aorta ITFs using time delays optimized for the individual and a GTF using averaged delay. With the use of ITFs, reconstructed aortic pressure was 121 +/- 19/69 +/- 9 mmHg and the root mean square error (RMSE), as measure of difference in wave shape, was 4.1 +/- 2.0 mmHg. With the use of the GTF, reconstructed pressure was 122 +/- 19/69 +/- 9 mmHg and RMSE 4.4 +/- 2.0 mmHg. The augmentation index (AI) of the measured aortic pressure was 26 +/- 13%, and with ITF and GTF the AIs were 28 +/- 12% and 30 +/- 11%, respectively. Details of the wave shape were reproduced slightly better with ITF but not significantly, thus individualization of pressure transfer is not effective in resting patients.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical indicator...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: