A photo-cured coated-wire calcium ion selective electrode for use in flow injection potentiometry
P W Alexander1, T Dimitrakopoulos, D B Hibbert
1Department of Physical Sciences, University of Tasmania, P.O. Box 1214, Launceston, Tasmania, 7250, Australia.
Abstract:
A multi-sensor cell containing a new photo-cured calcium ion selective electrode sensor is reported. Four membranes containing different components are prepared to determine the one with optimum selectivity and sensitivity. This is shown to consist of the N,N,N',N'-tetracyclohexyl-3-oxapentanediamide ligand (ETH 129) as the ionophore, 2-nitrophenyl octyl ether as the plasticiser and tetradodecyl ammonium tetrakis(4-chlorophenyl) borate as the lipophilic additive. The photo-curing process is applied after coating a thin membrane on a silver wire as substrate transducer to produce the calcium sensor. The curing process is demonstrated to be faster (1 min) than previous methods and does not require a nitrogen atmosphere for reproducible production of membrane response characteristics. Four sensors constructed with the identical optimum membrane are shown to function reproducibly in a multi-sensor flow-through cell using the steady-state mode of flow measurement, and an average calibration slope of 28.5+/-0.4 mV change per activity decade is observed over a log-linear concentration range between 0.01 and 10 mM. The sensor is also shown to respond to changes in pH. Hence, in the flow injection potentiometric mode, a constant carrier buffer composition of pH 8.3 is required for accurate potentiometric calcium determinations. The sensor is used to determine calcium in water samples by flow injection potentiometry. The accuracy of the electrode determination relative to atomic absorption spectroscopy was in the range 5-9% for three different water samples.
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Controlled-Current Coulometry: Overview
Potentiometry: Membrane Electrodes
Capillary Electrophoresis: Instrumentation
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...