Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 28, 2026

A Microfluidic Platform for High-throughput Single-cell Isolation and Culture
09:51

A Microfluidic Platform for High-throughput Single-cell Isolation and Culture

Published on: June 16, 2016

Sample pretreatment on microfabricated devices.

Jan Lichtenberg1, Nico F de Rooij, Elisabeth Verpoorte

  • 1SAMLAB, Institute of Microtechnology, University of Neuchâtel, CH-2007 Neuchâtel, Switzerland.

Talanta
|October 31, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microfluidic compartmentalization reveals that ferrostatin-1 restores directional mitochondrial transport in Aβ-challenged neurons.

Lab on a chip·2026
Same author

Microfluidic NMR for <i>operando</i> monitoring of drug-induced metabolic fluxes in liver tissue slices.

Lab on a chip·2026
Same author

Electrochemical Flow Reactors: Mass Transport, iR Drop, and Membrane-Free Performance with In-Line Analysis.

ACS electrochemistry·2025
Same author

Suppressing parasitic flow in membraneless diffusion-based microfluidic gradient generators.

Lab on a chip·2025
Same author

Exploring Surface-Enhanced Raman Spectroscopy of Pyrazine-2-Carbonitrile for Indirect Label-Free Albumin Quantification in an <i>In Vitro</i> Endothelium Permeability Assay.

Analytical chemistry·2025
Same author

Real-Time Monitoring of Oxygen-Consumption Rate in Mouse Liver Slices Incubated in Organ-on-a-Chip Devices.

Analytical chemistry·2024
Same journal

Maximizing molecular coverage in ultrahigh-resolution orbitrap analysis of marine dissolved organic matter using two-stage design-of-experiments strategy.

Talanta·2026
Same journal

A new HPLC-ICP-MS method for gadolinium speciation in freshwaters using ion exchange chromatography and aqueous mobile phases.

Talanta·2026
Same journal

Selective voltammetric determination of labile copper in unpretreated wine samples using a synthetic fungal-mimicking biointerface.

Talanta·2026
Same journal

Dual-engine amplification: Integrating catalytic hairpin assembly with CRISPR-Cas12a for ultrasensitive point-of-care testing of Chikungunya virus RNA.

Talanta·2026
Same journal

An ECL immunosensor based on the synergistic self-enhancement of CuCoFe-LDH with Luminol-PEI for ultrasensitive detection of AFP.

Talanta·2026
Same journal

Tailoring amine-rich porous monolith for the miniaturized solid phase extraction of phenolic environmental estrogens.

Talanta·2026
See all related articles

Integrating sample pretreatment into microfluidic devices is crucial for miniaturized total analysis systems (muTAS). This review overviews developments addressing sample variation and compatibility challenges for effective muTAS.

Area of Science:

  • Analytical Chemistry
  • Biotechnology
  • Microfluidics

Background:

  • Integrating sample pretreatment into microfluidic devices is a key challenge for miniaturized total analysis systems (muTAS).
  • Diverse sample matrices and the need for compatible pretreatment techniques complicate device development.
  • Pretreatment methods must align with microfluidic constraints regarding time, reagents, power, and sample volume.

Purpose of the Study:

  • To provide a comprehensive review of current advancements in microfluidic sample pretreatment.
  • To highlight the challenges and solutions associated with integrating sample preparation into microfluidic platforms.
  • To discuss the compatibility requirements for pretreatment techniques coupled with microfluidic analysis devices.

Main Methods:

More Related Videos

Digital Microfluidics for Automated Proteomic Processing
10:55

Digital Microfluidics for Automated Proteomic Processing

Published on: November 6, 2009

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
10:34

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection

Published on: January 7, 2022

Related Experiment Videos

Last Updated: Jun 28, 2026

A Microfluidic Platform for High-throughput Single-cell Isolation and Culture
09:51

A Microfluidic Platform for High-throughput Single-cell Isolation and Culture

Published on: June 16, 2016

Digital Microfluidics for Automated Proteomic Processing
10:55

Digital Microfluidics for Automated Proteomic Processing

Published on: November 6, 2009

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
10:34

The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection

Published on: January 7, 2022

  • Literature review of recent research on microfluidic sample pretreatment.
  • Analysis of various pretreatment techniques applicable to microfluidic systems.
  • Evaluation of compatibility factors including time, reagent, power, and sample volume.
  • Main Results:

    • Significant progress has been made in developing integrated sample pretreatment methods for microfluidics.
    • Various techniques like solid-phase extraction, filtration, and mixing have been successfully miniaturized.
    • Compatibility issues are being addressed through innovative microfluidic designs and reagent handling.

    Conclusions:

    • Successful integration of sample pretreatment is essential for realizing the full potential of muTAS.
    • Ongoing research focuses on enhancing the efficiency, versatility, and compatibility of microfluidic pretreatment.