Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Sensitive assay for oxygen solubility in molten alkali metal carbonates by indirect flame atomic absorption
Silvera Scaccia1, Stefano Frangini
1IDROCOMB, Hydrogen and Fuel Cells Project, ENEA, C.R. Casaccia, Via Anguillarese 301, I-00060 Rome, Italy.
Abstract:
A precise and accurate indirect analytical method for the assessment of O(2) solubility in molten (Li(0.62)K(0.38))(2)CO(3) and (Li(0.52)Na(0.48))(2)CO(3) is described. The method is based on the oxidation of Cr(2)(SO(4))(3) (added in excess to the melt) by the oxygenate species, which are formed inside the melt when it is in contact with oxygen gas, and subsequent determination of trace amount of Cr(VI) in withdrawn frozen melts by flame atomic absorption spectrometry (FAAS). The samples (1.0-2.0g) are dissolved in dilute hydrochloric acid at room temperature. The speciation of Cr(VI) is carried out by complexation with ammonium pyrrolidine dithiocarbamate (APDC), followed by extraction into methyl isobutyl ketone (MIBK), which is introduced directly into the flame. Optimisation of the flame composition provided maximum Cr signal in organic phase under lean acetylene-air flame. The separation and preconcentration parameters such as sample volume/extractant volume ratio, pH sample solution, chelating concentration and extraction time are evaluated. Under the optimised conditions Cr(VI) is efficiently separated from Cr(III), which exceeded 200-folds. The results of the analysis of synthetic samples using standards in MIBK medium give rise to recoveries of 98-99%. The Cr(VI) detection limit of 4x10(-6)gL(-1) using 12.5-fold preconcentration and relative standard deviation of 1% at the 0.10mgL(-1) level are obtained. The sampling-to-sampling reproducibility was typically 3-5% relative standard deviation. By changing the preconcentration factor and the dilution of the sample melt, it is possible to analyse oxygen concentrations in molten alkali metal carbonates as low as 1.5x10(-9)mol O(2) per gram melt.
More Related Videos
Related Concept Videos
Flame Photometry: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Flame Photometry: Overview
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...