Spectrophotometric simultaneous determination of nitroaniline isomers by orthogonal signal correction-partial least
Jahanbakhsh Ghasemi1, Ali Niazi
1Department of Chemistry, Faculty of Sciences, Razi University, Kermanshah 57167, Iran.
Abstract:
The simultaneous determination of nitroaniline isomer mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removes the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 200-500nm range for 21 different mixtures of nitroaniline isomers. Calibration matrices were containing 1-21, 1-15 and 1-18mugml(-1) of m-nitroaniline, o-nitroaniline and p-nitroaniline, respectively. The RMSEP for m-nitroaniline, o-nitroaniline and p-nitroaniline with OSC and without OSC were 0.6567, 0.2692, and 0.3134, and 1.3818, 1.2181, and 0.3953, respectively. This procedure allows the simultaneous determination of nitroaniline isomers in real matrix samples and good reliability of the determination was proved.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
NMR Spectrometers: Resolution and Error Correction