Speciation of arsenic in ground water samples: A comparative study of CE-UV, HG-AAS and LC-ICP-MS
Kazi Farzana Akter1, Zuliang Chen, Lester Smith
1Centre for Environmental Risk Assessment and Remediation, University of South Australia, Adelaide, SA 5095, Australia.
Abstract:
The performance of capillary electrophoresis-ultraviolet detector (CE-UV), hydride generation-atomic absorption spectrometry (HG-AAS) and liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) have been compared for the speciation of arsenic (As) in groundwater samples. Two inorganic As species, arsenite (As(III)), arsenate (As(V)) and one organo species dimethyl arsenic acid (DMA) were mainly considered for this study as these are known to be predominant in water. Under optimal analytical conditions, limits of detection (LD) ranging from 0.10 (As(III), AsT) to 0.19 (DMA) mug/l for HG-AAS, 100 (As(III), DMA) to 500 (As(V)) mug/l for CE-UV and 0.1 (DMA, MMA) to 0.2 (As(III), As(V)) mug/l for LC-ICP-MS, allowed the determination of the above three species present in these samples. Results obtained by all the three methods are well correlated (r(2)=0.996*** for total As) with the precision of <5% R.S.D. except CE-UV. The effect of interfering ions (e.g. Fe(2+), Fe(3+), SO(4)(2-) and Cl(-)) commonly found in ground water on separation and estimation of As species were studied and corrected for. Spike recovery was tested and found to be 80-110% at 0.5mug/l As standard except CE-UV where only 50% of the analyte was recovered. Comparison of these results shows that LC-ICP-MS is the best choice for routine analysis of As species in ground water samples.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...