Related Experiment Video
Updated: Jun 28, 2026

08:30
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[A method of controlling the X-ray generator with PLC technique]
Jin-yang Yin1, Yi-Fan Tang, Bin-Hong Chen
1Shanghai Medical Instrumentation College, 200093, Shanghai.
Summary
This study explores how Programmable Logic Controllers (PLCs) manage essential X-ray generator functions. The research details PLC integration for precise control over X-ray parameters, enhancing operational efficiency.
Area of Science:
- Engineering
- Physics
- Computer Science
Context:
- X-ray generators are critical in various scientific and medical applications.
- Precise control over generator parameters is essential for consistent results and safety.
- Traditional control systems can be complex and less adaptable.
Purpose:
- To investigate the application of Programmable Logic Controllers (PLCs) in managing X-ray generator parameters.
- To demonstrate the feasibility and benefits of using PLC technology for X-ray generator control.
- To provide a foundation for developing advanced, automated X-ray systems.
Summary:
- The research details the integration of a PLC to control fundamental parameters of an X-ray generator.
- Key parameters such as voltage, current, and exposure time are effectively managed by the PLC.
- This approach offers a robust and flexible method for X-ray generator operation.
Impact:
- Improved precision and reliability in X-ray generation.
- Potential for enhanced automation and remote control of X-ray equipment.
- Foundation for future advancements in X-ray system design and application.
Related Concept Videos
Control of Power Flow
There are several methods to control power flow in power systems:
Generator Voltage Control
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
Imaging Studies for Cardiovascular System III: X-Ray
The most common cardiovascular diagnostic test is an X-ray. It produces images of the heart, blood vessels, and adjacent structures.
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
The X̄ Chart
The x̄ chart is a statistical tool for monitoring the means in a process.
The x̄ chart, often known as the individual control chart, is a crucial tool in statistical process control. It is designed to monitor process behavior and performance over time and is widely used in various industries to ensure that processes are operating at their optimum capacity and within specified limits.
A x̄ chart is constructed by plotting individual measurements of a quality characteristic in the order in which...
The x̄ chart, often known as the individual control chart, is a crucial tool in statistical process control. It is designed to monitor process behavior and performance over time and is widely used in various industries to ensure that processes are operating at their optimum capacity and within specified limits.
A x̄ chart is constructed by plotting individual measurements of a quality characteristic in the order in which...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
Load-frequency control
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
