Related Experiment Video
Updated: Jun 28, 2026

Humanized NOG Mice for Intravaginal HIV Exposure and Treatment of HIV Infection
Published on: January 31, 2020
Quinacrine sterilization for human immunodeficiency virus-positive women
Déborah Randazzo Barbosa de Magalhães1, Cláudia Ramos de Carvalho Ferreira, Estefânia Barbosa Magalhães
1School of Medicine, Department of Obstetrics and Gynecology, Federal University of Minas Gerais, Belo Horizonte, Brazil.
Objective:
To evaluate the safety of nonsurgical quinacrine sterilization for HIV-positive (HIV+) women.
Design:
An open trial of quinacrine sterilization was carried out in women infected with HIV and women who were HIV negative (HIV-). Comparison of the results with the two groups provided an assessment of the safety and effectiveness of quinacrine sterilization for HIV+ women.
Setting:
University Medical School outpatient services.
Patient(S):
A total of 258 women who desired sterilization were offered quinacrine sterilization as a means of limiting family size. Sixty-four were HIV+, and 194 were HIV-. Women who were HIV+ had CD4 counts >200 and were otherwise healthy.
Intervention(S):
A modified Copper T intrauterine device inserter was used to place 252 mg of quinacrine, divided into seven pellets (36 mg each) into the uterine cavity. Three insertions of this formulation were performed, 1 month apart. Viral load and CD8 and CD4 lymphocytes were measured both before and after quinacrine sterilization and at follow-up visits. Pregnancies and adverse events were recorded carefully. A decrement life table was made to statistically analyze results. RESULT(S) AND MAIN OUTCOME MEASURE(S): No serious adverse event occurred in any patient in this study. Adverse effects related to quinacrine sterilization were abdominal cramping, vulvar itching, nausea, and vaginal bleeding. Vaginal bleeding was the only short-term side effect noted to occur more frequently in HIV-infected women after quinacrine sterilization. Among HIV+ women, 35.9% had complaints of increased bleeding, whereas only 8.2% of those who were HIV- had such complaints, which probably were insertion related. Viral load and the CD4+ and CD8+ lymphocyte measures displayed no statistically significant difference after quinacrine sterilization.
Conclusion(S):
Quinacrine sterilization is a safe method for the sterilization of HIV-infected women and has no short-term effect on the pathology of the disease.
Related Concept Videos
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Sexually Transmitted Infections