Related Experiment Video
Updated: Jun 26, 2026

Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
Dario Melilli1, Antonio Rallo, Angelo Cassaro
1Department of Oral Sciences, University of Palermo, Palermo, Italy.
Abstract:
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with addition-polymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after the second disinfection, carried out 6 hours after the first one (T3). Impressions which were not disinfected served as controls. When both impression materials were disinfected with SP, significant differences were detected among all measurements (P < 0.0001), with the exception of T2 vs T3 (P > 0.05). On the other hand, when MD was used, significant differences were found when T0 measurement was compared to T1, T2 and T3 measurements (P = 0.0043 for PE, and P = 0.0014 for PVS). The dimensional change of all material/disinfectant combinations was always
