An analysis of the strain field in biaxial Flexcell membranes for different waveforms and frequencies
Related Experiment Video
Updated: Jun 26, 2026

A Novel Stretching Platform for Applications in Cell and Tissue Mechanobiology
Published on: June 3, 2014
A Colombo1, P A Cahill, C Lally
1School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland.
Abstract:
Mechanical stimuli have been shown to affect cell behaviour in terms of proliferation, apoptosis, and protein expression. In terms of cardiovascular diseases, for example, endothelial and smooth muscle cells exposed to an abnormal strain environment have been associated with atherosclerosis and in-stent restenosis. The FX-4000 system (Flexercell Tension Plus System, Flexcell Corporation, McKeesport, Pennsylvania, USA) is an in-vitro system that is widely used to strain cells in order to evaluate their response to strain. The precision, accuracy, and repeatability of the strains controlled by the system are therefore crucial to analyse and interpret the results confidently. The aim of this study was to investigate the mechanical behaviour of the FX-4000 Flexercell six-well-plate silicon membranes for static and dynamic cyclic strains by measuring the maximum peak strain and analysing the change in the membrane deformation after cyclic strain for 0 h, 24 h, and 48 h at different strain amplitudes and frequencies. The results of the tests conducted demonstrate notable differences between the measured strains of the membranes in comparison with both the inputs and the outputs of the Flexcell software. The calibration method used by Flexcell International assumes that the strain values determined for a given vacuum pressure on the silicone membranes are reliable for different waveforms and frequencies. The data reported here clearly indicate that this is not the case. The results indicate that a unique calibration pressure-strain curve must be determined for each test given the viscoelastic nature of the Flexcell system. A new method to calibrate the machine in house was applied using new pressure-strain equations. This new calibration method has been presented and should enable researchers using the Flexcell machine to set up their cell experiments more accurately.
More Related Videos
08:41Equibiaxial Stretching Device for High Magnification Live-Cell Confocal Fluorescence Microscopy
Published on: June 13, 2025
16:27Biophysical Assays to Probe the Mechanical Properties of the Interphase Cell Nucleus: Substrate Strain Application and Microneedle Manipulation
Published on: September 14, 2011
Related Concept Videos
Three-Dimensional Analysis of Strain
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member is the...
Transformation of Plane Strain
Under plane strain conditions, typical for members where one dimension significantly exceeds the others, deformations and resultant strains are...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Mechanisms of Membrane-bending
Membrane bending can happen due to intrinsic changes in lipid composition or extrinsic association with different proteins. The proteins involved...