Related Experiment Video
Updated: Jun 26, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Susceptibility-weighted imaging at 3 Tesla delineates the optic radiation
Nobuyuki Mori1, Yukio Miki, Seiko Kasahara
1Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Objectives:
Some white matter tracts, including the optic radiation (OR), have recently been reported to be delineated as low signal intensity bands (LSBs) on T2*-weighted images at 7 T, presumably because of susceptibility effects caused by myelin.Susceptibility-weighted imaging (SWI) is more sensitive to magnetic susceptibility than T2*-weighted imaging. This study examined whether the LSBs, lateral to the lateral ventricles (LVs) on 3-T SWI, represent the OR.
Materials And Methods:
Subjects comprised 17 healthy volunteers. Transaxial and oblique coronal SWIs orthogonal to the long axes of the inferior horns of the LVs were acquired covering the entire OR at 3 T. For quantification of the LSBs, breadth and thickness of LSBs were measured on planes including: (a) the tip of the inferior horn of the LV, (b) the lateral geniculate body, (c) the trigone of the LV, and (d) the posterior horn of the LV. Distances between the temporal pole and most anterior tip (D) of each LSB were also measured. Diffusion tensor tractography of the OR was also compared with the LSB on SWI in 10 of the 17 subjects.
Results:
Mean and SD of LSB measurements were breadth: (a) 8.8 +/- 1.8 mm, (b) 18.6 +/- 1.7 mm, (c) 20.5 +/- 3.1 mm, (d) 23.9 +/- 4.1 mm; and thickness: (a) 1.7 +/- 0.4 mm, (b) 2.4 +/- 0.5 mm, (c) 3.7 +/- 0.5 mm, (d) 3.3 +/- 0.4 mm, respectively. Mean D was 32.0 +/- 4.0 mm. These measurements were consistent with the anatomic literature regarding the OR. D on the diffusion tensor tractography was 40.3 +/- 7.7 mm, which was significantly longer than that of the LSB on SWI (31.8 +/- 3.4) for the 10 subjects (P = 0.0002).
Conclusions:
SWI at 3 T can constantly delineate the OR. The present study includes novelty in reporting that the entire length of the OR is constantly depicted on SWI, a 3-dimensional high-resolution imaging sequence, at a clinically more widely available 3-T magnetic field.
Related Concept Videos
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies VII: Vascular Imaging
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

