Scintillation-induced jitter of projected light with centroid trackers
1Nutronics, Inc., 3357 Chasen Drive, Cameron Park, California 95682, USA. rholmes@nutroninc.com
Abstract:
When light radiating from a distant object passes through extended turbulence, the light is scintillated. Such scintillated light may be received by an optical system and passed to a camera in the focal plane, and used to track an object. Such trackers often use centroid trackers. Then a laser or other light may be projected back toward the object, steered by the centroid measured on the tracker. The presence of scintillation on the tracker return will cause a jitter error in the pointing of projected light, if the projected light's intensity differs from that of the incoming scintillation pattern. This error is caused by a lack of full-field conjugation of the tilt component of the received return. This error is considered, for horizontal path conditions, as a difference between centroid tilt and gradient tilt. The estimated error is typically not large, and is estimated by both simulation and analytic means, and these are found to agree for conditions of interest. The possibility of means for correction of this error is discussed briefly.
Related Concept Videos
Light Acquisition
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform magnetic...
Interference and Diffraction
Instantaneous Center of Zero Velocity
To analyze this, consider two points on the wheel: point A and point B. The absolute velocity of point B can be expressed as the vector sum of the absolute velocity of point A and the relative velocity of point B with respect to point A. To simplify this analysis,...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
IR Spectrometers