Updated: Jun 25, 2026

High-throughput Protein Expression Generator Using a Microfluidic Platform
09:26

High-throughput Protein Expression Generator Using a Microfluidic Platform

Published on: August 23, 2012

Cell-free protein expression in a microchannel array with passive pumping.

Ruba Khnouf1, David J Beebe, Z Hugh Fan

  • 1Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA.

Lab on a Chip
|February 12, 2009
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Use of liposomal irinotecan with 5-FU and oxaliplatin (NALIRIFOX) in neoadjuvant pancreatic adenocarcinoma: NEO-Nal-IRI trial.

The oncologist·2026
Same author

Diverse Bacterial Properties Influence Dispersal Along Fungal Networks.

Journal of fungi (Basel, Switzerland)·2026
Same author

CXCL13-CXCR5 Signaling in CD8<sup>+</sup> T Cell Recruitment and Lymphoid Immune Organization in Clear Cell Renal Cell Carcinoma.

bioRxiv : the preprint server for biology·2026
Same author

A Head and Neck Cancer Patient-Specific Microphysiological System for Predicting Response to Chemoradiation.

bioRxiv : the preprint server for biology·2026
Same author

Lymphatic Endothelial Cells Regulate Neutrophil Phenotypes and Function in a Microphysiological Model of Infection.

bioRxiv : the preprint server for biology·2026
Same author

Development of a Platform for <i>in-situ</i> Airborne Virus Detection by Interfacing RT-LAMP Assay with a Condensational Growth Collector.

Aerosol science and technology : the journal of the American Association for Aerosol Research·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
Same journal

A particulate blood-mimicking fluid with physiological biconcave geometry for microscale hemorheology.

Lab on a chip·2026
Same journal

Multicellular sensor arrays fabricated by capillary stamping for pattern-based odor discrimination.

Lab on a chip·2026
Same journal

A real-time microfluidic surveillance system for multiplex detection of heavy metal contamination in wastewater.

Lab on a chip·2026
See all related articles

This study demonstrates enhanced in vitro protein expression using a microfluidic device with passive pumping. This novel method increases protein yield while significantly reducing reagent costs for high-throughput applications.

Area of Science:

  • Biotechnology
  • Microfluidics
  • Biochemistry

Background:

  • In vitro protein expression is crucial for research and development.
  • Current methods can be reagent-intensive and lack high-throughput capabilities.

Purpose of the Study:

  • To develop a microfluidic device for enhanced in vitro protein expression using passive pumping.
  • To optimize protein yield and reduce reagent consumption.

Main Methods:

  • Utilized a polystyrene microfluidic device with 192 microchannels.
  • Employed passive pumping driven by surface tension differences between droplets.
  • Measured protein expression yield using luminescence assay for luciferase expression.

Main Results:

More Related Videos

Sealable Femtoliter Chamber Arrays for Cell-free Biology
13:44

Sealable Femtoliter Chamber Arrays for Cell-free Biology

Published on: March 11, 2015

Counting Proteins in Single Cells with Addressable Droplet Microarrays
12:25

Counting Proteins in Single Cells with Addressable Droplet Microarrays

Published on: July 6, 2018

Related Experiment Videos

Last Updated: Jun 25, 2026

High-throughput Protein Expression Generator Using a Microfluidic Platform
09:26

High-throughput Protein Expression Generator Using a Microfluidic Platform

Published on: August 23, 2012

Sealable Femtoliter Chamber Arrays for Cell-free Biology
13:44

Sealable Femtoliter Chamber Arrays for Cell-free Biology

Published on: March 11, 2015

Counting Proteins in Single Cells with Addressable Droplet Microarrays
12:25

Counting Proteins in Single Cells with Addressable Droplet Microarrays

Published on: July 6, 2018

  • Passive pumping enhanced protein expression yield through nutrient replenishment.
  • Expression yield correlated with nutrient solution delivery rate and frequency.
  • Yield was independent of expression solution volume under tested conditions.
  • Demonstrated significant reduction in reagent cost (125-800x less).
  • Conclusions:

    • Microchannel arrays enable efficient, high-yield, and cost-effective protein expression.
    • The system supports simultaneous optimization and high-throughput protein production.
    • Passive pumping is a viable strategy for enhancing cell-free expression systems.