Why does it take longer to read digital than film-screen screening mammograms? A partial explanation
Tamara Miner Haygood1, Jihong Wang, Deanna Lane
1Department of Diagnostic Radiology, Unit 1273, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030-4009, USA. Tamara.Haygood@mdanderson.org
Digital mammograms (DM) take longer to interpret than film-screen mammograms (FSM). Computer manipulation and longer viewing times for DM contribute to the increased interpretation duration.
Area of Science:
- Radiology
- Medical Imaging
Background:
- Digital screening mammograms (DM) are increasingly used but reported to have longer interpretation times than film-screen mammograms (FSM).
- Understanding the factors contributing to this time difference is crucial for optimizing workflow in radiology departments.
Purpose of the Study:
- To investigate the specific components of the mammogram interpretation process that contribute to the longer reading times associated with digital screening mammograms (DM) compared to film-screen mammograms (FSM).
Main Methods:
- A previous study's timed readings were utilized, focusing on computer manipulation times for DM and physical adjustments for FSM.
- Interpretation times were analyzed by subtracting manipulation times to estimate decision-making times for both modalities.
Main Results:
- Computer manipulation times for DM varied significantly (11 s to 113.8 s) depending on the complexity of image handling, while FSM adjustments were quicker (8.3 s to 12.1 s).
- Estimated decision-making times were substantially longer for DM (128.0 s to 202.2 s) compared to FSM (60.9 s to 146.3 s).
- Radiologists also appeared to spend more time actively viewing DM images before reaching a decision.
Conclusions:
- Computer manipulation contributes to the extended interpretation duration of digital screening mammograms.
- Radiologists' increased visual engagement with digital mammograms also plays a role in the longer reading times, suggesting workflow and display optimization may be needed.
Related Concept Videos
Magnetic Resonance Imaging
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...