Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Capillary flow-driven paper-based microfluidic sensor for NDMA detection in water.

Lab on a chip·2026
Same author

Integrated Magnetophoretic-Electrochemical platforms for portable detection of HER2 in breast cancer diagnosis.

Biosensors & bioelectronics·2026
Same author

Smartphone-Based Peptide Nucleic Acid (PNA) Probe-Assisted Potentiometric Biosensor for Point-of-Care Testing of SARS-CoV-2 Nucleic Acid.

Analytical chemistry·2026
Same author

Detection of Aerosolized Protein Using a Condensation Growth Tube Coupled with an Electrochemical Immunoassay on Screen-Printed Carbon Electrodes.

Analytical chemistry·2026
Same author

Capillary-Driven Duplex Microfluidic Device Enabling Simultaneous Electrochemical Immunoassays for Detecting SARS-CoV-2 and Respiratory Syncytial Virus.

ACS sensors·2026
Same author

Sponge-Based Flow Control in Laminate Capillary-Driven Electrochemical Microfluidic Devices for Viscous Sample Analysis.

Analytical chemistry·2026

Related Experiment Video

Updated: Jun 25, 2026

One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes
08:31

One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes

Published on: September 13, 2018

Microfluidic Protein Patterning on Silicon Nitride Using Solvent Extracted Poly(dimethylsiloxane) Channels.

Xinya He1, David S Dandy, Charles S Henry

  • 1Department of Chemistry, Colorado State University, Fort Collins, CO 80523.

Sensors and Actuators. B, Chemical
|February 25, 2009
PubMed
Summary

This study demonstrates that solvent-extracted poly(dimethylsiloxane) (E-PDMS) microfluidic channels improve biomolecular patterning on various substrates. E-PDMS enhances protein immobilization and signal generation for applications like immunoassays.

More Related Videos

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Related Experiment Videos

Last Updated: Jun 25, 2026

One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes
08:31

One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes

Published on: September 13, 2018

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Area of Science:

  • Biomolecular engineering
  • Microfluidics
  • Surface chemistry

Background:

  • Biomolecular patterning is crucial for creating selective sensing devices, such as protein, DNA, and cell microarrays.
  • Microfluidic devices offer a promising platform for developing robust biomolecular patterning methods.
  • Substrate and microfluidic channel material selection critically impacts signal generation and minimizes noise from non-specific adsorption.

Purpose of the Study:

  • To evaluate different substrates and microfluidic channel materials for optimal protein patterning.
  • To compare the performance of native poly(dimethylsiloxane) (PDMS) and solvent-extracted PDMS (E-PDMS) microchannels for microfluidic patterning.
  • To assess the suitability of improved microfluidic patterning for multi-layer immunoassay development.

Main Methods:

  • Proteins were patterned onto polystyrene, glass, and silicon nitride substrates using microfluidic channels.
  • Two types of PDMS microchannels were used: native PDMS and solvent-extracted PDMS (E-PDMS).
  • Patterning quality was assessed by measuring fluorescence intensity of immobilized proteins.

Main Results:

  • E-PDMS microfluidic channels exhibited superior patterning characteristics compared to native PDMS channels across all tested substrates.
  • Higher fluorescence intensity of immobilized protein was observed using E-PDMS channels, indicating improved signal generation.
  • The optimized microfluidic patterning approach was successfully applied to construct two- and four-layer immunoassays.

Conclusions:

  • Solvent-extracted PDMS (E-PDMS) is a superior material for microfluidic channels in biomolecular patterning applications.
  • E-PDMS microfluidics enhance protein immobilization and reduce non-specific adsorption, leading to improved assay performance.
  • This microfluidic patterning technique provides a robust foundation for developing advanced multiplexed immunoassays and biosensors.