Effect of superparamagnetic iron oxide on tumor-to-liver contrast at T2*-weighted gradient-echo MRI: comparison between 3.0T and 1.5T MR systems
Related Experiment Video
Updated: Jun 25, 2026

Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration
Published on: May 19, 2023
Tonsok Kim1, Takamichi Murakami, Masatoshi Hori
1Department of Radiology, Osaka University Graduate School of Medicine, Osaka, Japan. kim@radiol.med.osaka-u.ac.jp
Purpose:
To compare 3.0T and 1.5T MR systems in terms of the effect of superparamagnetic iron oxide (SPIO) on tumor-to-liver contrast in T2*-weighted gradient-echo MRI.
Materials And Methods:
SPIO-enhanced gradient-echo MR images of the liver with four different TEs (3, 5.3, 6.5, and 8.5 msec) were obtained by means of 1.5T and 3.0T systems. Quantitative analyses of relative signal intensities (SIs) and relative tumor contrast and qualitative analyses of image quality and lesion conspicuity of the liver were performed in 22 patients, 16 of whom had malignant liver tumors.
Results:
With both 1.5T and 3.0T, at TE=8.4 msec, the relative SI of liver and relative tumor contrast were significantly (P<0.01) lower and higher, respectively, than that for any of the other TEs. There were no significant differences in the relative SI of the liver, relative tumor contrast, image quality, and tumor conspicuity for the same TE between the 1.5T and 3.0T systems.
Conclusion:
Our results showed that the effect of SPIO on tumor-to-liver contrast at T2*-weighted gradient-echo imaging was similar for the 1.5T and 3.0T systems, and that the 8.4-msec TE was optimal of the four TEs used in this study at 3.0T.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...