Related Experiment Video
Updated: Jun 24, 2026

Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light
Published on: September 12, 2014
Illumination-induced errors associated with suns-V(OC) measurements of silicon solar cells
Thomas Roth1, Jochen Hohl-Ebinger, Daniela Grote
1Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, 79110 Freiburg, Germany. thomas.roth@ise.fraunhofer.de
Abstract:
I(SC)-V(OC) curves measured by the suns-V(OC) method are widely used for solar cell characterization due to its being unaffected by series resistance effects. A common setup for this measurement system uses a xenon photoflash for illumination purposes, resulting in a fast acquisition of the suns-V(OC) measurement data during the decaying edge of one flash. However, the use of a xenon photoflash accompanies also several disadvantages. Measurement errors are expected from the imperfect illumination homogeneity on the measurement stage. Also the discrepancy of the flash spectrum compared to the standard AM 1.5G spectrum leads to spectral mismatch between the sample and monitor cells when their spectral response differs. In addition, the divergence of the flash light leads to different illumination densities on the sample and the monitor cell if the height of these two cells differs. In this article these photoflash-caused measurement errors are investigated in detail, analyzing the resulting deviation in illumination density. The error due to an inhomogeneous illumination is negligible under most circumstances, while the error due to a spectral mismatch has to be considered but can be reduced drastically if an additional short-pass filter is used. The measurement error due to different cell highs should be taken into account but can be accounted for using an analytical correction.
More Related Videos
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for Cu(In,Ga)Se2 Solar Cells
Published on: October 3, 2018
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
P-N junction
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Photoelectric Effect