Temperature changes during ultrasonic irrigation with different inserts and modes of activation
Marco Zeltner1, Ove A Peters, Frank Paqué
1University of Zurich Dental School, Division of Endodontology, Zurich, Switzerland.
Journal of Endodontics
|April 7, 2009
Summary
Passive ultrasonic irrigation using continuous flow did not significantly heat irrigants. However, depositing irrigants before activation with larger K-files or nickel-titanium (NiTi) instruments effectively increased root canal temperatures.
Area of Science:
- Endodontics
- Biomaterials Science
- Dental Materials
Background:
- Passive ultrasonic irrigation (PUI) is a common endodontic technique.
- Understanding temperature changes during PUI is crucial for procedural safety and efficacy.
- The delivery method of irrigants may influence temperature modulation during ultrasonic activation.
Purpose of the Study:
- To evaluate and compare temperature variations in root canals during passive ultrasonic irrigation under different irrigant delivery methods.
- To assess the impact of various ultrasonic instrument types (NiTi and stainless steel K-files) and sizes on irrigant temperature.
Main Methods:
- Extracted maxillary canines were instrumented to size #45.
- Thermocouples measured temperatures at 3, 6, and 9 mm from the apex.
- Two groups were tested: continuous irrigant flow (Group 1) and pre-deposited irrigant (Group 2).
- Ultrasonic activation was performed using noncutting NiTi inserts or stainless steel K-files (#15, #25, #35).
Main Results:
- Continuous flow (Group 1) resulted in initial temperature drops and temperatures near baseline, with lower readings in the coronal third.
- Pre-deposited irrigants (Group 2) showed significant temperature rises (up to 7.7°C in the coronal third).
- Larger K-files (#35) and NiTi inserts generated higher temperature increases compared to smaller K-files (#15).
- Continuous flow negated the heating potential of ultrasonic activation.
Conclusions:
- Continuous irrigant flow during PUI minimizes temperature increases, potentially enhancing safety.
- Pre-depositing irrigants and using larger instruments (NiTi or stainless steel K-files) can significantly elevate irrigant temperature.
- Instrument type and size influence the degree of irrigant warming during ultrasonic activation when irrigants are pre-deposited.