Hemodialysis facility-based quality-of-care indicators and facility-specific patient outcomes
Eduardo Lacson1, Weiling Wang, J Michael Lazarus
1Clinical Science, Epidemiology, and Research, Fresenius Medical Care North America, Waltham, MA 02451-1457, USA. elacsonj@fmc-na.com
Background:
We evaluated whether incremental achievement of up to 8 facility quality goals was associated with improvement in facility-specific mortality and hospitalization rates.
Study Design:
Prospective observational study.
Setting & Participants:
1,085 Fresenius Medical Care, North America facilities providing hemodialysis (HD) for 25 or more patients during January 2006.
Measurements:
The facility average for the period up to December 31, 2006, was used to determine achievement of each goal for equilibrated Kt/V, missed HD treatments, hemoglobin level, bicarbonate level, albumin level, phosphorus level, fistulae, and HD catheters. Linear regression models were used to relate facility-wide achievement of goals with facility-specific hospital days and standardized mortality ratios.
Results:
Most facilities (64%) achieved 2 to 4 of 8 goals, with only 8% meeting more than 5 quality goals. Achieving more than 5 goals averaged 3.5 fewer hospital days/patient-year and 20% lower standardized mortality ratios (all P < 0.001). The incremental number of goals met also was associated with improvement in facility mortality (P < 0.001) and hospital days (P < 0.001). Catheter and albumin level goals were achieved least (6% and 9% of facilities, respectively), but they had the best outcomes. Facilities achieving more than 5 goals had older patients (64.0 versus 61.5 years; P < 0.001), fewer African American patients (16% versus 38%; P < 0.001), and fewer women (44% versus 46%; P = 0.003) compared with the average.
Limitations:
Observational design with residual confounding from unmeasured patient-, facility-, and treatment-related factors.
Conclusions:
Achieving more facility quality goals was significantly associated with better facility-based measurements of patient outcomes. Although these results do not establish a causal relationship, findings agree with the present practice of monitoring facility performance for continuous quality improvement.