Related Experiment Video
Updated: Jun 23, 2026

Multiplexing Focused Ultrasound Stimulation with Fluorescence Microscopy
Published on: January 7, 2019
A heterogeneous nonlinear attenuating full-wave model of ultrasound
Gianmarco F Pinton1, Jeremy Dahl, Stephen Rosenzweig
1Ecole Superieure de Physique et Chimie Industrielles, Paris, France.
Abstract:
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). Three-dimensional solutions of the equation are verified with water tank measurements of a commercial diagnostic ultrasound transducer and are shown to be in excellent agreement in terms of the fundamental and harmonic acoustic fields and the power spectrum at the focus. The linear and nonlinear components of the algorithm are also verified independently. In the linear nonattenuating regime solutions match results from Field II, a well established software package used in transducer modeling, to within 0.3 dB. Nonlinear plane wave propagation is shown to closely match results from the Galerkin method up to 4 times the fundamental frequency. In addition to thermoviscous attenuation we present a numerical solution of the relaxation attenuation laws that allows modeling of arbitrary frequency dependent attenuation, such as that observed in tissue. A perfectly matched layer (PML) is implemented at the boundaries with a numerical implementation that allows the PML to be used with high-order discretizations. A -78 dB reduction in the reflected amplitude is demonstrated. The numerical algorithm is used to simulate a diagnostic ultrasound pulse propagating through a histologically measured representation of human abdominal wall with spatial variation in the speed of sound, attenuation, nonlinearity, and density. An ultrasound image is created in silico using the same physical and algorithmic process used in an ultrasound scanner: a series of pulses are transmitted through heterogeneous scattering tissue and the received echoes are used in a delay-and-sum beam-forming algorithm to generate a images. The resulting harmonic image exhibits characteristic improvement in lesion boundary definition and contrast when compared with the fundamental image. We demonstrate a mechanism of harmonic image quality improvement by showing that the harmonic point spread function is less sensitive to reverberation clutter.
Related Concept Videos
Sound Waves: Interference
Standing Waves in a Cavity
Interference and Superposition of Waves
Interference occurs in mechanical waves, such as sound waves, waves on a string, and surface water waves. Mechanical waves correspond to the physical displacement of particles. Hence,...
Sound Waves
Sound waves are longitudinal in most fluids because fluids cannot sustain any lateral pressure. In solids, however, shear forces help in propagating the disturbance in the lateral direction as well. Hence,...
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
The de Broglie Wavelength

