Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Noncompartmental Analysis: Statistical Moment Theory00:56

Noncompartmental Analysis: Statistical Moment Theory

Noncompartmental analyses leverage statistical moment theory to examine time-related changes in macroscopic events, encapsulating the collective outcomes stemming from the constituent elements in play. Statistical moment theory is a mathematical approach used to describe the time course of drug concentration in the body without assuming a specific compartmental model. SMT provides insights into drug absorption, distribution, metabolism, and elimination by treating drug concentration versus time...
Noncompartmental Analysis: Mean Residence Time01:05

Noncompartmental Analysis: Mean Residence Time

According to statistical moment theory, mean residence time (MRT) is an important measure in pharmacokinetics. MRT can be defined as the expected mean of a probability density function distribution. It provides valuable insights into drug disposition in the body.
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Properties of DTFT II01:24

Properties of DTFT II

In the study of discrete-time signal processing, understanding the properties of the Discrete-Time Fourier Transform (DTFT) is crucial for analyzing and manipulating signals in the frequency domain. Several properties, including frequency differentiation, convolution, accumulation, and Parseval's relation, offer powerful tools for signal analysis.
The frequency differentiation property is illustrated by considering a DTFT pair and differentiating both sides with respect to ω. Multiplying by j...
Drug Concentration Versus Time Correlation01:15

Drug Concentration Versus Time Correlation

The plasma drug concentration-time curve is a crucial tool in pharmacokinetics, representing the drug's concentration in plasma at different time intervals post-administration. This curve illustrates the drug's journey from absorption into the systemic circulation, distribution to body tissues, and eventual elimination through excretion or biotransformation.
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the system's...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The impact of QT lag compensation on dynamic assessment of ventricular repolarization: reproducibility and the impact of lead selection.

Pacing and clinical electrophysiology : PACE·2001
Same author

The relationship between QT intervals and mortality in ambulant patients with chronic heart failure. The united kingdom heart failure evaluation and assessment of risk trial (UK-HEART)

European heart journal·1999
Same author

Prospective study of heart rate variability and mortality in chronic heart failure: results of the United Kingdom heart failure evaluation and assessment of risk trial (UK-heart).

Circulation·1998
Same author

Effects of digoxin on time domain measures of heart rate variability in patients with stable chronic cardiac failure: withdrawal and comparison group studies.

International journal of cardiology·1997
Same author

The correction of autonomic dysfunction in cirrhosis by captopril.

Journal of hepatology·1997
Same author

Caffeine restriction has no role in the management of patients with symptomatic idiopathic ventricular premature beats.

Heart (British Cardiac Society)·1996
Same journal

[Extrasystoles in endurance athletes].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[AI-Assisted ECG diagnostics : Classical test statistics still apply].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Perioperative complications during transvenous pacemaker and defibrillator implantation].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Late complications after atrial fibrillation ablation : Diagnosis and management].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Position paper of the German Society of Cardiology-quality criteria for performing catheter ablation of atrial fibrillation: executive summary].

Herzschrittmachertherapie & Elektrophysiologie·2026
See all related articles

Related Experiment Video

Updated: Jun 22, 2026

Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia
10:05

Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia

Published on: January 27, 2018

Dynamic QT interval analysis : methodological aspects.

J M Neilson1

  • 1Department of Medical Physics, The Royal Infirmary, 1 Lauriston Place, EH3 9YW, Edinburgh, UK.

Herzschrittmachertherapie & Elektrophysiologie
|June 2, 2009
PubMed
Summary
This summary is machine-generated.

Electronic computing allows continuous QT interval tracking from 24-hour ambulatory ECG recordings. This method precisely monitors QT variations over hours with minimal uncertainty.

More Related Videos

Quantifying Cytoskeleton Dynamics Using Differential Dynamic Microscopy
06:37

Quantifying Cytoskeleton Dynamics Using Differential Dynamic Microscopy

Published on: June 15, 2022

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
07:41

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0

Published on: June 5, 2017

Related Experiment Videos

Last Updated: Jun 22, 2026

Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia
10:05

Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia

Published on: January 27, 2018

Quantifying Cytoskeleton Dynamics Using Differential Dynamic Microscopy
06:37

Quantifying Cytoskeleton Dynamics Using Differential Dynamic Microscopy

Published on: June 15, 2022

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
07:41

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0

Published on: June 5, 2017

Area of Science:

  • Cardiology
  • Biomedical Engineering
  • Medical Instrumentation

Background:

  • The QT interval on electrocardiogram (ECG) recordings is a critical indicator of cardiac repolarization.
  • Accurate and continuous monitoring of QT interval variations is essential for assessing cardiac health and identifying potential risks.
  • Traditional methods for QT interval measurement can be time-consuming and may lack the precision required for dynamic analysis.

Purpose of the Study:

  • To evaluate the feasibility and accuracy of continuous QT interval tracking using advanced electronic computing.
  • To assess the precision of monitoring QT interval variations over extended periods from ambulatory ECG recordings.

Main Methods:

  • Utilizing advanced electronic computing for the analysis of 24-hour ambulatory ECG data.
  • Implementing precise algorithms for continuous QT interval calculation.
  • Emphasizing the importance of appropriate lead selection and proper electrode placement (hook-up technique) for signal quality.

Main Results:

  • Continuous tracking of the QT interval is achievable with modern electronic computing.
  • The method demonstrates high precision, with root-mean-square (RMS) uncertainty limited to a few milliseconds.
  • QT interval variations can be reliably followed for extended durations (hours).

Conclusions:

  • Advances in electronic computing facilitate accurate, continuous QT interval monitoring from ambulatory ECG.
  • Precise QT interval tracking over hours is possible with meticulous attention to technical details like lead selection and hook-up.
  • This technology holds promise for improved cardiac monitoring and risk assessment.