Design Example01:23

Design Example

The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
Properties of Fourier Transform I01:21

Properties of Fourier Transform I

The application of Fourier Transform properties in radio broadcasting is multifaceted, enabling significant advancements in the way signals are transmitted and received. Key areas where these properties are utilized include simultaneous multi-channel transmission, audio clip speed adjustments, live broadcast delays for different time zones, audio frequency adjustments, and signal demodulation.
In radio broadcasting, multiple audio signals often need to be transmitted simultaneously. The Fourier...
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Signal and System01:26

Signal and System

A signal x(t) is a set of data or a time function representing a variable of interest. Signals typically convey information about a phenomenon, such as atmospheric temperature, humidity, human voice, television images, a dog's bark, or birdsongs. More generally, a signal can be a function of more than one independent variable. For instance, images depend on horizontal and vertical positions and can be regarded as two-dimensional signals. However, this text will focus on one-dimensional signals...
Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Properties of the z-Transform I01:17

Properties of the z-Transform I

The z-transform is a fundamental tool in digital signal processing, enabling the analysis of discrete-time systems through its various properties. It is an invaluable tool for analyzing discrete-time systems, offering a range of properties that simplify complex signal manipulations. One fundamental property is linearity. For any two discrete-time signals, the z-transform of their linear combination equals the same linear combination of their individual z-transforms. This property is essential...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Community dynamics during de novo colonization of the nascent peri-implant sulcus.

International journal of oral science·2025
Same author

Community dynamics during de novo colonization of the nascent peri-implant sulcus.

Research square·2024
Same author

Acceptability, Feasibility, and Effectiveness of Immersive Virtual Technologies to Promote Exercise in Older Adults: A Systematic Review and Meta-Analysis.

Sensors (Basel, Switzerland)·2023
Same author

Adding Haptic Feedback to Virtual Environments With a Cable-Driven Robot Improves Upper Limb Spatio-Temporal Parameters During a Manual Handling Task.

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2020
Same author

Modulation of electric brain responses evoked by pitch deviants through transcranial direct current stimulation.

Neuropsychologia·2017
Same author

A Virtual Reality avatar interaction (VRai) platform to assess residual executive dysfunction in active military personnel with previous mild traumatic brain injury: proof of concept.

Disability and rehabilitation. Assistive technology·2016
Same journal

Continuous tracking of aortic aneurysm diameter with peripheral pulse waves: a computational framework combining sequential Markov chain Monte Carlo with Kalman filtering.

Physiological measurement·2026
Same journal

The 2026 global roadmap for textile-integrated wearable technologies in health.

Physiological measurement·2026
Same journal

Augmenting single-lead ECG interpretation through QRS waveform decomposition and rotation.

Physiological measurement·2026
Same journal

Dynamic Beat-to-Beat Blood Pressure Estimation using a Multi-modal Wearable Deep Learning Approach.

Physiological measurement·2026
Same journal

Dual warm-start fusion versus attention-based fusion in low-label ECG-PCG classification: a controlled ablation study.

Physiological measurement·2026
Same journal

Inter-patient multi-label ECG classification via low-rank adaptation fine-tuned large language models with dynamic graph convolutional network.

Physiological measurement·2026
See all related articles

Related Experiment Video

Updated: Jun 22, 2026

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
15:25

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters

Published on: February 4, 2018

A multi-frequency EIT system design based on telecommunication signal processors.

Nicolas Robitaille1, Robert Guardo, Isabelle Maurice

  • 1Institut de génie biomédical, Ecole Polytechnique de Montréal, Montréal, QC H3T 1J4, Canada.

Physiological Measurement
|June 4, 2009
PubMed
Summary
This summary is machine-generated.

A new multi-frequency electrical impedance tomography system offers advanced cardiopulmonary monitoring. This system utilizes telecommunications-grade processors for precise impedance measurements, enabling detailed imaging.

More Related Videos

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

Related Experiment Videos

Last Updated: Jun 22, 2026

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
15:25

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters

Published on: February 4, 2018

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

Area of Science:

  • Biomedical Engineering
  • Medical Imaging
  • Electrical Engineering

Background:

  • Cardiopulmonary monitoring is crucial for patient care.
  • Existing monitoring methods have limitations in providing detailed physiological data.
  • Electrical Impedance Tomography (EIT) offers a non-invasive imaging modality.

Purpose of the Study:

  • To design and characterize a multi-frequency electrical impedance tomography (EIT) system for cardiopulmonary monitoring.
  • To leverage telecommunications digital signal processors for enhanced EIT performance.
  • To evaluate the system's accuracy and signal-to-noise ratio for potential clinical application.

Main Methods:

  • Developed a two-module EIT system: a scan-head with a 16-electrode array and a base-station with digital synthesizers and down-converters.
  • Simultaneously measured four complex variables (potential difference, applied currents, ground current) at eight frequencies (10 kHz to 2 MHz).
  • Utilized specialized digital signal processors for high-speed data acquisition and processing.

Main Results:

  • Achieved a mean signal-to-noise ratio of 43 dB and accuracy of 95.4% at a 5 Hz frame rate for frequencies between 70 to 950 kHz.
  • Demonstrated successful reconstruction of in vitro and in vivo time-difference images.
  • System frequencies are programmable with high resolution (2 mHz).

Conclusions:

  • The designed multi-frequency EIT system is suitable for cardiopulmonary monitoring.
  • The use of telecommunications processors enhances measurement precision and speed.
  • The system shows promise for non-invasive, real-time physiological imaging.