Characterization of Proteins by Size-Exclusion Chromatography Coupled to Multi-Angle Light Scattering (SEC-MALS)
Published on: June 20, 2019
An SEC/MALS study of alternan degradation during size-exclusion chromatographic analysis
André M Striegel1, Samantha L Isenberg, Gregory L Côté
1Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA. striegel@chem.fsu.edu
Abstract:
Ultrahigh-molar-mass (M) polymers such as DNA, cellulose, and polyolefins are routinely analyzed using size-exclusion chromatography (SEC) to obtain molar mass averages, distributions, and architectural information. It has long been contended that high-M polymers can degrade during SEC analysis; if true, the inaccurate molar mass information obtained can adversely affect decisions regarding processing and end-use properties of the macromolecules. However, most evidence to the effect of degradation has been circumstantial and open to alternative interpretation. For example, the shift in SEC elution volume as a function of increased chromatographic flow rate, observed using only a concentration-sensitive detector, may be the result of degradation or of elution via a nondegradatory slalom chromatography mechanism. Here, using both concentration-sensitive and multiangle static light-scattering detection, we provide unambiguous evidence that the polysaccharide alternan actually degrades during SEC analysis. The decrease in molar mass and size of alternan with increasing flow rate, measured using light scattering, allows ruling out an SC mode of elution and can only be interpreted as due to degradation. These findings demonstrate the extreme fragility of ultrahigh-M polymers and the care that must be taken for accurate characterization.
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology