Absolute Molar Mass Determination in Mixed Solvents. 3. Accuracy of ∂n/∂c Values Obtained by Assuming 100% SEC Mass
1Chemical Sciences Division, National Institute of Standards and Technology (NIST), 100 Bureau Drive, MS 8390, Gaithersburg, MD 20899-8390, USA.
Abstract:
Accurate values of the specific refractive index increment (∂n/∂c) are essential to the accurate determination of molar mass averages, distributions, and related macromolecular parameters by, among others, size-based separations with online static light scattering and differential refractive index (DRI) detection. Examined here is the 100% mass recovery method of calculating the ∂n/∂c of dilute macromolecular solutions, when employing mixed solvents in a size-based separation (e.g., size-exclusion chromatography or SEC) with DRI detection. This method has been used successfully in the past for determining the ∂n/∂c of various polyelectrolytes. It is quicker, generally simpler, and less sample-intensive than its offline, batch-mode DRI counterpart. Whether or not the 100% mass recovery method allows for the necessary solvent equilibration within the immediate vicinity of the polymer chain during a chromatographic run, so as to allow for accurate determination of ∂n/∂c in SEC/DRI experiments, is evaluated here. This is done using a set of three narrow-dispersity linear polystyrene standards covering a 40-fold range in molar mass, dissolved in a 25:75 mix of tetrahydrofuran and N,N-dimethyl formamide. Results are compared to those previously obtained by the batch-mode method and from calculations involving the accurately known molar masses of the polymers and refractive indices of the solvents. The 100% mass recovery method of obtaining ∂n/∂c values, while of great help for determining the ∂n/∂c of, e.g., polyelectrolytes, does not appear able to overcome the obstacle of preferential solvation when analyzing macromolecules in a mix of non-isorefractive solvents with dissimilar second virial coefficients.
More Related Videos
Related Concept Videos
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
High-Resolution Mass Spectrometry (HRMS)
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Mass Spectrum: Interpretation
Chemical Ionization (CI) Mass Spectrometry
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...