Related Experiment Video
Updated: Jun 22, 2026

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
Published on: April 14, 2023
A new sterilization technique of bovine pericardial biomaterial using microwave radiation
Yury Shamis1, Shital Patel, Alex Taube
1Swinburne University of Technology, Vic 3122, Melbourne, Australia.
Abstract:
Bioprosthetic valves created from chemically treated natural tissues such as bovine pericardial biomaterial are used as heart valve scaffolds. Methods currently available for sterilization of biomaterial for transplantation include the application of gamma radiation and chemical sterilants. These techniques, however, can be problematic because they can be expensive and lead to a reduction in tissue integrity. Therefore, improved techniques are needed that are cost effective and do not disrupt the physical properties, functionality, and lifespan of the valvular leaflets. This study examined a novel technique using nonthermal microwave radiation that could lead to the inactivation of bacteria in bovine pericardial biomaterial without compromising valve durability. Two common pathogenic species of bacteria, Escherichia coli and Staphylococcus aureus, were used as test microorganisms. Optimized microwave parameters were used to determine whether inactivation of pathogenic bacteria from bovine pericardium could be achieved. In addition, the effect of microwave sterilization on tissue integrity was examined. The mechanical properties (assessed using dynamic mechanical analysis) and tensile strength testing (using a Universal Tensile Tester) as well as thermal analysis (using thermogravimetric analysis and differential scanning calorimetry) indicated that microwave sterilization did not compromise the functionality of bovine pericardial biomaterial. Scanning electron microscopy imaging and cytotoxicity testing also confirmed that the structure and biocompatibility of transplant biomaterial remained unaltered after the sterilization process. Results from the application of this new microwave (MW) sterilization technique to bovine pericardium showed that near-complete inactivation of the contaminant bacteria was achieved. It is concluded that nonthermal inactivation of pathogenic bacteria from bovine pericardial biomaterial could be achieved using microwave radiation.
More Related Videos
08:01Semi-Minimal Invasive Method to Induce Myocardial Infarction in Rats and the Assessment of Cardiac Function by an Isolated Working Heart System
Published on: June 11, 2020
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...