High-resolution optical coherence tomography visualization of LASIK flap displacement

Camila Haydée Rosas Salaroli1, Yan Li, David Huang

  • 1Center for Ophthalmic Optics and Lasers, Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.

Summary

Laser vision correction (LASIK) can have complications like flap striae. High-resolution Fourier-domain optical coherence tomography (FD-OCT) effectively visualized and managed a subtle flap gap missed by standard examination.