Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Solution Concentration and Dilution02:59

Solution Concentration and Dilution

The relative amount of a given solution component is known as its concentration. Often, though not always, a solution contains one component with a concentration that is significantly greater than that of all other components. This component is called the solvent and may be viewed as the medium in which the other components are dispersed or dissolved. Solutions in which water is the solvent are, of course, very common on our planet. A solution in which water is the solvent is called an aqueous...
Formation of Concentrated Urine01:23

Formation of Concentrated Urine

There is a gradient of solutes in the interstitial fluid from the renal cortex through the medulla, known as the medullary osmotic gradient. The juxtamedullary nephrons establish and maintain this gradient using countercurrent mechanisms with loops extending deep into the medulla. These nephrons also use countercurrent mechanisms to regulate urine volume and concentration. The interaction between the descending and ascending limbs of the nephron loop creates an osmotic gradient through...
Precipitate Formation and Particle Size Control01:16

Precipitate Formation and Particle Size Control

In precipitation gravimetry, the precipitating agent should react specifically or selectively with the analyte. While a specific reagent reacts with the analyte alone, a selective reagent can react with a limited number of chemical species.
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Principles Of Column Chromatography01:13

Principles Of Column Chromatography

The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
Precipitation Processes01:12

Precipitation Processes

The experimental conditions in a gravimetric analysis should be optimized to maximize the particle size and purity of the obtained precipitate. Ideally, the concentration of the precipitating reagent should be low with effective stirring to maintain low relative supersaturation for the growth of large crystals. In homogeneous precipitation, the precipitant is slowly generated by a chemical reaction in the solution to avoid local reagent excesses. For example, urea decomposes gradually to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The association of high body mass index with the safety and efficacy of sacituzumab govitecan in patients with metastatic triple-negative breast cancer from the ASCENT study.

ESMO open·2025
Same author

A simple, accurate method for determining wet and dry weight concentrations of plant cell suspension cultures using microcentrifuge tubes.

Plant cell reports·2013
Same author

Possible high absorptance and low emittance selective surface for high temperature solar thermal collectors.

Applied optics·2010
Same author

Minimum-mirror-area single-stage solar concentrators.

Optics letters·2009
Same author

Trouble with farms at the Census Office: an evaluation of farm statistics from the censuses of 1851-1881 in England and Wales.

The Agricultural history review·2009
Same author

SERPINB12 is a novel member of the human ov-serpin family that is widely expressed and inhibits trypsin-like serine proteinases.

The Journal of biological chemistry·2001
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Jun 20, 2026

Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
09:00

Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics

Published on: October 27, 2017

Practical concentrators attaining maximal concentration

E Harting, D R Mills, J E Giutronich

    Optics Letters
    |August 21, 2009
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    A Small Volume Procedure for Viral Concentration from Water
    07:28

    A Small Volume Procedure for Viral Concentration from Water

    Published on: February 3, 2015

    Tangential Flow Ultrafiltration: A &ldquo;Green&rdquo; Method for the Size Selection and Concentration of Colloidal Silver Nanoparticles
    12:47

    Tangential Flow Ultrafiltration: A “Green” Method for the Size Selection and Concentration of Colloidal Silver Nanoparticles

    Published on: October 4, 2012

    Related Experiment Videos

    Last Updated: Jun 20, 2026

    Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics
    09:00

    Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass (ADG) Fresnel Lens for Concentrating Photovoltaics

    Published on: October 27, 2017

    A Small Volume Procedure for Viral Concentration from Water
    07:28

    A Small Volume Procedure for Viral Concentration from Water

    Published on: February 3, 2015

    Tangential Flow Ultrafiltration: A &ldquo;Green&rdquo; Method for the Size Selection and Concentration of Colloidal Silver Nanoparticles
    12:47

    Tangential Flow Ultrafiltration: A “Green” Method for the Size Selection and Concentration of Colloidal Silver Nanoparticles

    Published on: October 4, 2012