High-efficiency four-wave sum and difference mixing in Hg vapor.

Optics Letters
|August 25, 2009
PubMed
Summary

Researchers utilized mercury vapor for nonlinear frequency upconversion, achieving 5 kW peak power at 1251 Å. This study demonstrates efficient generation of tunable vacuum ultraviolet radiation using mercury vapor as a nonlinear medium.

Related Concept Videos

The Thermodynamics of Mixing01:28

The Thermodynamics of Mixing

Mixing is a fascinating phenomenon in thermodynamics, particularly when considering the Gibbs energy of a mixture at constant temperature and pressure. This energy, denoted as G, tends to decrease during spontaneous mixing processes, offering insights into the composition changes that occur.Imagine two ideal gases, initially separated in different containers, with amounts nA and nB, respectively, both at a temperature T and pressure p. The chemical potentials of these gases have their 'pure'...
Hess's Law03:40

Hess's Law

There are two ways to determine the amount of heat involved in a chemical change: measure it experimentally, or calculate it from other experimentally determined enthalpy changes. Some reactions are difficult, if not impossible, to investigate and make accurate measurements for experimentally. And even when a reaction is not hard to perform or measure, it is convenient to be able to determine the heat involved in a reaction without having to perform an experiment.
Sum and Difference OpAmps01:22

Sum and Difference OpAmps

Operational amplifiers (op-amps) are versatile devices that extend beyond amplification. In this context, two specific op-amp configurations are explored: the summing and difference amplifiers.
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons01:03

¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons

Protons in identical electronic environments within a molecule are chemically equivalent and have the same chemical shift. The replacement test is a useful tool to identify chemical equivalence and predict NMR spectra. A substituent replaces each of the protons being examined and the resulting molecules are compared. If the same molecule is obtained, the protons are equivalent or homotopic. Replacement of any hydrogens in ethane by chlorine yields chloroethane because all six protons are...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...