Accuracy, limits, and approximation01:28

Accuracy, limits, and approximation

Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling01:26

Influence of Earth's Curvature and Atmospheric Refraction on Leveling

During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...
The Uncertainty Principle04:08

The Uncertainty Principle

Werner Heisenberg considered the limits of how accurately one can measure properties of an electron or other microscopic particles. He determined that there is a fundamental limit to how accurately one can measure both a particle’s position and its momentum simultaneously. The more accurate the measurement of the momentum of a particle is known, the less accurate the position at that time is known and vice versa. This is what is now called the Heisenberg uncertainty principle. He mathematically...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Geometric bowing effect of a laser beam.

Applied optics·2010
Same author

Moire deflectometry with a focused beam: radius of curvature, microscopy, and thickness analysis.

Applied optics·2010
Same author

Refractive index measurement of optical windows by an interferometric-deflectometric method.

Applied optics·2010
Same author

Comparison and combined operation of a moire deflectometer, Fizeau interferometer, and schlieren device.

Applied optics·2010
Same author

Universal method for determining the focal length of optical systems by moire deflectometry.

Applied optics·2010
Same author

High-sensitivity reflection-transmission moire deflectometer.

Applied optics·2010
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Jun 20, 2026

The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
12:14

The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

Published on: August 12, 2013

Fundamental limit on accuracy in interferometry.

O Kafri

    Optics Letters
    |September 16, 2009
    PubMed
    Summary
    This summary is machine-generated.

    A new golden rule quantifies fringe resolution limits, accounting for mechanical vibration. Moiré deflectometry offers superior signal-to-noise ratio compared to conventional interferometer systems limited by vibration isolation.

    More Related Videos

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
    11:47

    Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments

    Published on: February 27, 2013

    Related Experiment Videos

    Last Updated: Jun 20, 2026

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
    11:47

    Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments

    Published on: February 27, 2013

    Area of Science:

    • Optical metrology
    • Precision measurement

    Background:

    • Interferometer systems are crucial for high-precision measurements.
    • Mechanical vibrations significantly limit the fringe resolution in conventional interferometry.

    Purpose of the Study:

    • To derive a fundamental rule for evaluating fringe resolution limits.
    • To assess the impact of mechanical vibration on fringe resolution.
    • To compare moiré deflectometry with conventional interferometry.

    Main Methods:

    • Derivation of a golden rule from basic principles.
    • Analysis of mechanical vibration effects on fringe resolution.
    • Comparative study of interferometer systems and moiré deflectometry.

    Main Results:

    • A golden rule for fringe resolution limit evaluation is established.
    • Conventional interferometers are limited to approximately 1/1000 fringe due to vibration isolation.
    • Moiré deflectometry demonstrates potential for a significantly better signal-to-noise ratio.

    Conclusions:

    • Mechanical vibration is a critical factor limiting fringe resolution in interferometry.
    • Moiré deflectometry presents a promising alternative for enhanced precision measurements.