Related Experiment Video
Updated: Jun 20, 2026

Quantitative Measure of Lung Structure and Function Obtained from Hyperpolarized Xenon Spectroscopy
Published on: November 10, 2023
Effects of diffusion time on short-range hyperpolarized (3)He diffusivity measurements in emphysema
David S Gierada1, Jason C Woods, Andrew J Bierhals
1Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri 63105, USA. gieradad@wustl.edu
Diffusion time impacts hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) measurements in emphysema. Longer diffusion times decrease ADC, but this effect is independent of emphysema severity, confirming ADC
Area of Science:
- Pulmonary Medicine
- Radiology
- Medical Imaging Physics
Background:
- Emphysema is a chronic lung disease characterized by alveolar destruction.
- Hyperpolarized helium-3 (³He) magnetic resonance imaging (MRI) is a promising technique for assessing lung structure and function.
- Apparent diffusion coefficient (ADC) measurements in ³He MRI can quantify diffusion characteristics within the lungs.
Purpose of the Study:
- To investigate the influence of varying diffusion times on short-range ³He MRI diffusion measurements.
- To evaluate this effect across a spectrum of emphysema severities.
Main Methods:
- ³He diffusion MRI was performed on 19 human lung specimens with diverse emphysema levels.
- Three diffusion times (1.6, 5.0, and 10.0 msec) were used at a constant b value.
- Emphysema severity was assessed using mean ADC and an ADC index, with quantitative histology (mean linear intercept) obtained for comparison.
Main Results:
- Mean ADC values decreased significantly with increasing diffusion time (1.6 msec: 0.46 cm²/sec, 5.0 msec: 0.40 cm²/sec, 10.0 msec: 0.37 cm²/sec; P < 0.0001).
- The observed decrease in ADC with longer diffusion times was not correlated with emphysema severity.
- Strong correlations were found between ADC values (at all tested diffusion times) and quantitative histology (mean linear intercept), indicating ADC's robustness in reflecting emphysema.
Conclusions:
- The effect of diffusion time on ADC in ³He MRI is independent of emphysema severity.
- ADC measurements in ³He MRI are a reliable indicator of emphysema, correlating well with histological findings.
- These findings are crucial for standardizing diffusion time parameters in ³He MRI for accurate emphysema assessment.
Related Concept Videos
External and Internal Respiration
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting their diffusion into...
Protein Diffusion in the Membrane
Chronic Obstructive Pulmonary Disease II: Emphysema
