Temperature-stable spun elliptical-core optical-fiber current transducer

Optics Letters
|October 6, 2009
PubMed
Summary

A novel optical fiber current transducer demonstrates temperature stability. It utilizes a Sagnac interferometer to effectively cancel temperature-dependent effects in spun birefringent fibers for accurate electrical measurements.

Related Concept Videos

Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
Instrument Transformers01:23

Instrument Transformers

Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Energy Stored In A Coaxial Cable01:31

Energy Stored In A Coaxial Cable

A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...