Compound-specific delta34S analysis of volatile organics by coupled GC/multicollector-ICPMS
Alon Amrani1, Alex L Sessions, Jess F Adkins
1Division of Geological and Planetary Sciences, California Institute of Technology, 1200 East California Boulevard, Pasadena, California, USA. aamrani@caltech.edu
Abstract:
We have developed a highly sensitive and robust method for the analysis of delta(34)S in individual organic compounds by coupled gas chromatography (GC) and multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). The system requires minimal alteration of commercial hardware and is amenable to virtually all sample introduction methods. Isobaric interference from O(2)(+) is minimized by employing dry plasma conditions and is cleanly resolved at all masses using medium resolution on the Thermo Neptune MC-ICPMS. Correction for mass bias is accomplished using standard-sample bracketing with peaks of SF(6) reference gas. The precision of measured delta(34)S values approaches 0.1 per thousand for analytes containing >40 pmol S and is better than 0.5 per thousand for those containing as little as 6 pmol S. This is within a factor of 2 of theoretical shot-noise limits. External accuracy is better than 0.3 per thousand. Integrating only the center of chromatographic peaks, rather than the entire peak, offers significant gain in precision and chromatographic resolution with minimal effect on accuracy but requires further study for verification as a routine method. Coelution of organic compounds that do not contain S can cause degraded analytical precision. Analyses of crude oil samples show wide variability in delta(34)S and demonstrate the robustness and precision of the method in complex environmental samples.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.