Related Experiment Video
Updated: Jun 19, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
Three distinct directions of intramural activation reveal nonuniform side-to-side electrical coupling of ventricular
Bryan J Caldwell1, Mark L Trew, Gregory B Sands
1Auckland Bioengineering Institute, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.
Background:
The anisotropy of cardiac tissue is a key determinant of 3D electric propagation and the stability of activation wave fronts in the heart. The electric properties of ventricular myocardium are widely assumed to be axially anisotropic, with activation propagating most rapidly in the myofiber direction and at uniform velocity transverse to this. We present new experimental evidence that contradicts this view.
Methods And Results:
For the first time, high-density intramural electric mapping (325 electrodes at approximately 4x4x1-mm spacing) from pig left ventricular tissue was used to reconstruct 3D paced activation surfaces projected directly onto 3D tissue structure imaged throughout the same left ventricular volume. These data from 5 hearts demonstrate that ventricular tissue is electrically orthotropic with 3 distinct propagation directions that coincide with local microstructural axes defined by the laminar arrangement of ventricular myocytes. The maximum conduction velocity of 0.67+/-0.019 ms(-1) was aligned with the myofiber axis. However, transverse to this, the maximum conduction velocity was 0.30+/-0.010 ms(-1), parallel to the myocyte layers and 0.17+/-0.004 ms(-1) normal to them. These orthotropic conduction velocities give rise to preferential activation pathways across the left ventricular free wall that are not captured by structurally detailed computer models, which incorporate axially anisotropic electric properties.
Conclusions:
Our findings suggest that current views on uniform side-to-side electric coupling in the heart need to be revised. In particular, nonuniform laminar myocardial architecture and associated electric orthotropy should be included in future models of initiation and maintenance of ventricular arrhythmia.
More Related Videos
14:39Isolation and Functional Characterization of Human Ventricular Cardiomyocytes from Fresh Surgical Samples
Published on: April 21, 2014
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Excitation-Contraction Coupling in Skeletal Muscles
When an action potential...
Structure of Cardiac Muscles
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials